实验研究了冶金工艺过程产生的硫酸铜废液中铝的测定方法。采用氨水(1+1)使铝以氢氧化铝沉淀的形式与主体溶液分离,然后用EDTA络合法测定铝的质量浓度;对该硫酸铜废液中铜、铁干扰离子、溶液的酸度、EDTA络合反应温度等条件进行了一系列的实验,解决了硫酸铜废液中铝的测定难题。该方法与分光光度法比较,简单快速,分析成本低廉;通过对不同硫酸铜废液中铝的质量浓度测定,相对标准偏差为0.071%~0.930%(n=6),样品测定值与络天青S分光光度法测定值相符合。

Copper sulfate waste solution generated in metallurgical process is studied in determining aluminum . Ammonia (1+1) is used to separate aluminum in the form of aluminum hydroxide precipitation from the principal part of the solution ,and then the aluminum mass concentration is determined by EDTA complexometry .A series of ex-periments are conducted on the parameters such as copper and iron ionic interference ,solution acidity and the temper-ature of the EDTA complexation reaction ,solving the problems of the determination of the aluminum in this copper sul-fate waste solution .This method compared with spectrophotometry is simple , rapid and has lower analysis cost .The method through the determination in copper sulfate solution with different mass fraction ,obtains a relative standard de-viation of 0.071 %-0.930 %(n=6),and sample measurements are consistent with the azure S value determined by spectrophotometry .

参考文献

[1] 董锦平,陈涛,邹公伟.铝对人体健康的影响[J].环境监测管理与技术,1998(05):9-11.
[2] 谭涌霞,毕树平,干宁,魏宗波.铬蓝黑R-示波计时电位法快速测定天然水中不同形态的铝浓度[J].分析科学学报,2001(03):177-181.
[3] 沈含熙;汤园平 .高选择性荧光试剂:7 -(8 -喹啉偶氮) -8 -羟基喹啉-5 -磺酸测定痕量铝[J].冶金分析,1995,15(05):1-4.
[4] 张寒琦.仪器分析[M].北京:高等教育出版社,2009
[5] 李景梅,贾宝山,翟庆洲,田丽霞.分光光度法测定铝的进展[J].岩矿测试,2006(01):64-67.
[6] 何新锋.二甲酚橙-CTMAB光度法测定矿石中微量铝[J].冶金分析,1999(05):60.
[7] 钟国秀,杨浩义,黄清华.酸碱滴定法测定铝锰合金中铝量[J].冶金分析,2007(06):64-66.
[8] 梁瑞英.EDTA滴定法快速测定铝锰合金中铝[J].冶金分析,2001(03):60-61.
[9] 李景梅,贾宝山,翟庆洲,田丽霞.分光光度法测定铝的进展[J].岩矿测试,2006(01):64-67.