ECR离子源的等离子体阻抗对其微波传输与阻抗匹配设计至关重要.在中国科学院近代物理研究所现有的2.45 GHz ECR质子源上,对等离子体阻抗进行了测量.首先用水吸收负载代替等离子体负载测量得到了所用微波窗阻抗,然后根据质子源测量数据,推算得到了等离子体阻抗.实验结果表明,脊波导输出端阻抗与后续负载不完全匹配,等离子体阻抗随微波功率变化呈非线性.这些结果为ECR离子源过渡匹配和微波窗的设计提供了参考依据.
参考文献
[1] | TAYLORT MOURIS J E Nucl Instr and Meth A,1991,309(1/2):37. |
[2] | TAYLOR T,WILLS J S C.Nucl Instru and Meth A,1991,309:37. |
[3] | SHERMAN J D,FIGUEROA T L,HANSBOROUGH L D,et al.Review of Scientific Instrume,2002,73 (2):917. |
[4] | GOBIN R,BEAUVAIS P Y,DELFERRIERE O,et al.Review of Scientific Instrume,2008,79 (2):02B303. |
[5] | REN Haitao.Research on Compact High-current High-brihtness 2.45 GHz Permanent Magnet ECR Ion Source and its Applications ID].Beijing:College of Physical sicence of Graduate University of CAS & Institute of Heavy Ion Physics of Peking University,2012:42-45 (in Chinese).(任海涛.紧凑型高流强高亮度全永磁2.45 GHz ECR离子源及其应用的研究[D].北京:中国科学院研究生院物理科学学院和北京大学重离子物理研究所,2012:42-45.) |
[6] | CELONA L,CIAVOLA G,GAMMINO S.Review of Scientific Instruments,1998,69(2):1113. |
[7] | KIM J D,KIM S H,KIM H J,et al.Journal of the Korean Physical Society,2012,60(6):907. |
[8] | POZAR D M.Microwave Engineering(Third Edition)[M].Bei-jing:Publishing House of Electronics Industry,2006:66-223 (in Chinese).(POZARDM.微波工程(第三版)[M].张肇仪,译.北京:电子工业出版社,2006:66-223.) |