欢迎登录材料期刊网

材料期刊网

高级检索

参比电极对监测混凝土中钢筋的电位至关重要。使用凝胶作为电极内部电解质、水泥浆作为渗透层,制成 Ag/AgCl 凝胶参比电极。在混凝土模拟液中测试了电极电位的稳定性、电极的温度系数以及氯离子含量对电位的影响,通过动电位和恒电流极化测试了电极的抗极化性能,并在混凝土中进一步研究了电极电位的时变特性。结果表明,电极电位有良好的稳定性和可靠性,电极温度系数较小,氯离子含量对电极电位的影响可以忽略,电极抗极化性能优良。研制的电极可用于实时监测混凝土内部钢筋的腐蚀电位,为钢筋混凝土构件寿命预测提供参考。

The reference electrode was important for monitoring the potential of steel in concrete.The solid Ag/AgCl gel reference electrode was fabricated by applying the polymer gel as electrolyte,and the cement mortar as the bottom layer.The potential variation of electrodes,the temperature coefficient of electrodes and the influence of chloride concentration on the potential were examined in simulated concrete solutions.The performance of resisting polarization of electrodes was also detected by potentiodynamic and galvanostatic tests.Moreover,further research on the time-variant characteristic of potential by embedding the electrodes in concretew was studied.Results revealed that this reference electrode showed good stability and reliability.The electrode exhibited small temperature coefficient and the electrode potential was affected little by the chloride concentration.In addition,the electrode showed good per-formance of resisting polarization.The Ag/AgCl gel reference electrodes can be embedded in concrete to monitor the real-time corrosion potential of reinforcement steel,which can provide reference for life prediction.

参考文献

[1] 樊玲;卫军;彭述权;刘栋;董荣珍.一种可用于混凝土内部固态MnO2参比电极研究[J].传感技术学报,2014(6):709-714.
[2] 樊玲;卫军;彭述权;董荣珍.碱性电解质溶液对埋入式MnO2参比电极性能试验[J].武汉理工大学学报,2013(12):130-134.
[3] S.P. Karthick;S. Muralidharan;V. Saraswathy;K. Thangavel.Long-term relative performance of embedded sensor and surface mounted electrode for corrosion monitoring of steel in concrete structures[J].Sensors and Actuators, B. Chemical,2014:303-309.
[4] G. S. Duffo;S. B. Farina;C. M. Giordano.Characterization of solid embeddable reference electrodes for corrosion monitoring in reinforced concrete structures[J].Electrochimica Acta,20093(3):1010-1020.
[5] P. Castro;A.A. Sagues;E.I. Moreno.Characterization of Activated Titanium Solid Reference Electrodes for Corrosion Testing of Steel in Concrete[J].Corrosion: The Journal of Science and Engineering,19968(8):609-617.
[6] Ueli M. Angst;Rob Polder.Spatial variability of chloride in concrete within homogeneously exposed areas[J].Cement and Concrete Research,2014:40-51.
[7] Angst, U;Elsener, B;Larsen, CK;Vennesland, O.Potentiometric determination of the chloride ion activity in cement based materials[J].Journal of Applied Electrochemistry,20103(3):561-573.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%