通过研究阴极保护中电绝缘装置内腐蚀的形貌、位置、穿孔速度,发现了绝缘装置内腐蚀的规律;用电化学等效电路法分析了电绝缘装置非保护侧发生内腐蚀穿孔的原因、影响因素与程度、充要条件,并提出了防止绝缘装置内腐蚀穿孔的理论依据和技术措施.

The corrosion process of the electrical insulating device is revealed by examining the morphology,location,and perforation rate of the internal corrosion.The causes,the influence factors,and necessary and sufficient conditions required for the internal corrosion are analyzed by equivalent circuit method as well.Finally,the theoretical basis and the technical measures for the prevention of the internal corrosion perforation are put forward.