消除基体干扰是石墨炉原子吸收光谱法测定铁矿石试样中痕量铅的一个难题。实验通过将铅标准溶液系列加入到铁矿石标准样品溶液中以绘制标准加入校准曲线,然后再用建立的标准加入校准曲线对其他铁矿石试样中铅进行测定以消除铁矿石的基体干扰。据此,建立了标准加入校准法-石墨炉原子吸收光谱法( GFAAS )测定铁矿石试样中痕量铅的方法。实验表明,设置灰化程序为350℃保持30 s,600℃保持15 s,原子化温度为1600℃、保持4 s,标准加入校准曲线的相关系数为0.9998,方法的检出限为0.43 mg/kg。方法应用于铁矿石标准样品中铅的测定,测定值和认定值吻合性较好,相对标准偏差(RSD,n=6)小于7.0%。采用方法对铁矿石标准样品和实际样品进行加标回收试验,回收率在93%~98%之间。

The elimination of matrix interference was a difficulty in determination of trace lead in iron ore by graph-ite furnace atomic absorption spectrometry ( GFAAS) . The standard solution series of lead were added into certified reference material solution of iron ore to prepare standard addition calibration curve. Then, the established standard addition calibration curve was used for determination of lead in other iron ore samples to eliminate the matrix inter-ference. On the basis of this, a determination method of trace lead in iron ore sample was established by GFAAS combined with standard addition calibration method. The experimental conditions were optimized as follows:the as-hing program was 35℃ keeping for 30 s and 600℃ keeping for 12 s;the atomization temperature was 1 600℃and kept for 4 s. The results showed that the correlation coefficient of standard addition calibration curve was 0. 999 8. The detection limit of method was 0. 43 mg/kg. The proposed method was applied to the determination of lead in certified reference material of iron ore. The results were consistent with the certified values. The relative standard deviation (RSD, n=6) was less than 7. 0%. The recovery tests of certified reference material and actual sample of iron ore were conducted according to the experimental method. The recoveries were between 93% and 98%.

参考文献

[1] 亢德华;于媛君;王铁;杨丽荣;顾继红.电感耦合等离子体质谱法测定铸铁中镁、锡、镧、铈、锑和铅[J].冶金分析,2011(6):54-57.
[2] 李奋;吴文启;谢晓雁;苏信宇;梁晓明;卢金荣.离子交换分离石墨炉原子吸收光谱法测定高纯铟中痕量铅[J].冶金分析,2013(12):19-23.
[3] 林立;姚继军;杨仁康;孙继红.悬浮进样-石墨炉原子吸收光谱法直接测定化妆品中的铅[J].岩矿测试,2013(4):644-648.
[4] 宋国辉;宋彦辉;范晓华.土壤中铅的测定方法研究[J].中国卫生工程学,2013(2):160-161,163.
[5] 杨小丽;王迪民;汤志勇.石墨炉原子吸收光谱法测定磷矿石中微量铅和铬[J].岩矿测试,2010(1):51-54.
[6] 曾泽;卢琪;谢琰;蒋维旗;张庆娟.石墨炉原子吸收光谱法测定磷酸中铅镉[J].冶金分析,2009(5):66-68.
[7] 曾泽;刘永梅;赵景红;谢琰.石墨炉原子吸收光谱法测定滑石中酸溶痕量铅镉[J].冶金分析,2008(6):66-68.
[8] 徐文军.微波消解石墨炉原子吸收光谱法测定蔬菜中痕量铅[J].理化检验-化学分册,2007(06):485-487.
[9] 方从权;褚敬东;李春;徐玉梅.石墨炉原子吸收光谱法测定茶叶中的铅[J].分析试验室,2007(11):112-114.