分析了电网的系统频率波动对监测变压器套管tanδ的影响,提出一种基于基波频率修正原理的介质损耗因数测量方法.该方法将电压、电流信号在时域内过滤其直流分量,修正所测电信号的基波频率,对原信号采用样条插值法进行插值计算,并进行整周期反复采样,截取整周期样本长度进行快速傅里叶计算,得到基波电压和基波电流的相位夹角,求出其余角的正切值即为介质损耗因数.仿真试验及现场应用的结果表明:采用该方法可实现对变压器套管介质损耗的准确测量.

The effect of grid system frequency fluctuations on the monitoring transformer bushing was analyzed, and a method of measuring the dielectric dissipation factor based on the fundamental frequency correction was proposed. The DC components of the voltage and current signals were filtered in time domain through this method, and the fundamental frequency of measured electric signals was corrected. Then the origin signals were calculated with spline interpolation and sampled repeatedly in a whole period. The phase angle between fundamental voltage and current was obtained by fast Fourier calcula-tion for the samples in the whole period, and the tangent value of the coangle was obtained, which is the dielectric dissipation factor. This method can accurately measure the dielectric dissipation factor of transformer bushing according to the results of simulation and practical application.

参考文献

[1] 黄新波;章云;李俊峰.变电站容性设备介损在线监测系统设计[J].高电压技术,2008(8):1594-1598.
[2] 吕泽承;张炜;邓雨荣;陶松梅;吴秋丽.不同电压下电容型设备介质损耗测试值的等效性分析[J].电力建设,2013(10):49-52.
[3] 徐志钮;律方成.基于改进基波相位分离法的介质损耗角测量[J].电网技术,2006(8):41-45,55.
[4] 李泽文;曾祥君;覃丹;易琛;曾祥淼.基于FPGA的容性设备介质损耗在线测量系统[J].电力系统自动化,2006(12):92-96.
[5] Günther Ramm;Harald Moser.From the calculable AC resistor to capacitor dissipation factor determination on the basis of time constants[J].IEEE Transactions on Instrumentation and Measurement,20012(2):286-289.
[6] 左自强;徐阳;曹晓珑;刘斌.计算电容型设备介质损耗因数的相关函数法的改进[J].电网技术,2004(18):53-57.
[7] 党晓强;刘俊勇;刘念;吴集光.小波消噪在容性设备tanδ在线测量中的应用[J].高电压技术,2006(3):45-48.
[8] 田成凤.变压器电容式套管电容量及介损的正确测量[J].电力自动化设备,2010(04):147-149.
[9] 徐志钮;律方成;李和明.加Blackman-Harris窗插值算法仿真介损角测量[J].高电压技术,2007(3):104-108.
[10] M. Wang;A. J. Vandermaar;K. D. Srivastava.Review of condition assessment of power transformers in service[J].IEEE Electrical Insulation Magazine,20026(6):12-25.
[11] 徐志钮;律方成;赵丽娟.基于加汉宁窗插值的谐波分析法用于介损角测量的分析[J].电力系统自动化,2006(2):81-85.