高级检索

饲料样品经1%三氯乙酸-二甲基亚砜提取,Waters Oasis MCX柱净化,超高效液相色谱分离,最终采用电喷雾串联四极杆质谱进行检测.结果表明,三聚氰胺在饲料中的含量范围为10~5 000 μg/kg时,线性关系良好(r>0.99).在10~100 μg/kg 的添加水平范围内的平均回收率为83% ~94% ,相对标准偏差为4.2% ~6.5% .该方法的检出限为10 μg/kg.

参考文献

[1] Tadeo J L,Sanchez-Brunete C,Perez R A,et al.J Chroma-togr A,2000,882(1/2):175
[2] Sugita T,Ishiwata H,Yoshihira K,et al.Bull Environ Contam Toxicol,1990,44:567
[3] FDA/ORA Forensic Chemistry Center.GC-MS screen for the presence of melamine and cyanuric acid.[2007-04-10].http://www.fda.gov/cvm/MelaminePresence.htm
[4] Sancho J V,Ibanez M,Grimalt S,et al.Anal Chim Acta,2005,530:237
[5] Sancho J V,Pozo O J,Zamora T,et al.J Agric Food Chem,2003,51(15):4 202
[6] Ni Q Y.Fujian Analysis & Testing (倪沁颜.福建分析测试),2008,17(1):57
[7] Yokley R A,Mayer L C,Rezaaiyan R,et al.J Agric Food Chem,2000,48:3 352
[8] Ding T,Xu J Z,Li J Z,et al.Chinese Journal of Chromatography (丁涛,徐锦忠,李健忠,等.色谱),2008,26(1):6
[9] Ren B Z,Li C,Yuan X L,et al.Journal of Chemical Industry and Engineering (China) (任保增,李晨,袁晓亮,等.化工学报),2003,54(7):1 001