欢迎登录材料期刊网

材料期刊网

高级检索

采用电化学聚合的方法将氨基黑10B染料分子修饰到玻碳电极表面,制备了聚氨基黑10B修饰电极,其稳定性和重复性较好.该修饰电极对维生素B6(VB6)的氧化有明显的电催化作用,VB6的氧化峰电位负移,电流显著增加.利用微分脉冲伏安和安培检测技术对VB6进行了定量检测,检测限均可达到0.05μmol/L,与已报道的修饰电极比较,是目前最低的.将该修饰电极用于不同药物制剂中VB6浓度的测定,操作方便、快速,方法灵敏,准确度高.

参考文献

[1] Nepota A J,Dmiani P C,OliVieri A C.Chemometrics Assisted Spectroscopic Determination of Vitamin B6,Vitamin B12 and Dexamethasone in Injectables[J].J Pharm Biomed Anal,2003,31(4):621-627.
[2] Pharmacopoeia Commission of the Ministry of Public Health of People's Republic of China.Pharmacopoeia of People's Republic of China[M].Beijing:Chemical Industry Press,2005:847(in Chinese).中华人民共和国卫生部药典委员会.中华人民共和国药典[M].北京:化学工业出版社,2005:847.
[3] ZHANG Jianyun,HUANG Longquan,HAYAKAWA Takashi,et al.Analysis of Vitamin B6 Derivatives in Biological Samples with High Performance Liquid Chromatography[J].Chem J Chinese Univ,2004,25(4):638-640(in Chinese).张剑韵,黄龙全,早川享志,等.采用高效液相色谱技术分析生物体内维生素B6[J].高等学校化学学报,2004,25(4):638-640.
[4] Gatti R,Gioia M G,Cavrini V.Determination of Cinchona Alkaloids and Vitamin B6 by High-performance Liquid Chromatography with Fluorescence Detection[J].Anal Chim Acta,2004,512(1):85-91.
[5] LI Shaodan,PENG Weifang.Simultaneous Determination of Vitamin B6,Nicotinamide and Calcium Pentothenate by RPHPLC[J].Phys Test Chem Anal Part B(Chem Anal),2009,45(7):800-802(in Chinese).李少旦,彭卫芳.反相高效液相色谱法同时测定维生素B6、烟酰胺和泛酸钙[J].理化检验-化学分册,2009,45(7):800-802.
[6] Alwarthan A A,Aly F A.Chemiluminescent Determination of Pyridoxine Hydrochloride in Pharmaceutical Samples Using Flow Injection[J].Talanta,1998,45(6):1131-1138.
[7] Ca(n)ada M J A,Reguera M I P,Díaz A M.Selective Determination of Pyridoxine in the Presence of Hydrosoluble Vitamins Using a Continuous-flow Solid Phase Sensing Device with UV Detection[J].Int J Pharm,2000,202:113-120.
[8] YAN Yuan,XU Jingou,LIN Jiang,et al.Simultaneous Determination of Vitamin B2 and B6 Using Three-dimensional Fluorescence Spectrometry by Detecting Total Fluorescence Intensity[J].Chem J Chinese Univ,1997,18(6):877-879(in Chinese).鄢远,许金钩,林江,等.三维荧光光谱总体积积分法同时测定维生素B2和B6[J].高等学校化学学报,1997,18(6):877-879.
[9] EI-Gindy A.Spectrophotometric and LC Determination of Two Binary Mixtures Containing Pyridoxine Hydrochloride[J].J Pharm Biomed Anal,2003,32(2):277-286.
[10] Jin W,Zhang J.Monitoring Pyridoxine by Capillary Zone Electrophoresis with Electrochemical Detection[J].Electroanalysis,2000,12:465-467.
[11] Schreiner M,Razzasi E,Lui W.Determination of Water-soluble Vitamins in Soft Drinks and Vitamin Supplements Using Capillary Electrophoresis[J].Nahrung/Food,2003,47:243-247.
[12] Hernández S R,Ribero G G,Goicoechea H C.Enhanced Application of Square Wave Voltammetry with Glassy Carbon Electrode Coupled to Multivariate Calibration Tools for the Determination of B6 and B12 Vitamins in Pharmaceutical Preparations[J].Talanta,2003,61(5):743-753.
[13] Siddiqui I,Piter K S.Voltammetric Determination of Vitamins in a Pharmaceutical Formulation[J].J Pharm Biomed Anal,2001,26(5/6):1009-1015.
[14] Teixeira M F S,Marino G,Dockal E R,et al.Voltammetric Determination of Pyridoxine(Vitamin B6)at a Carbon Paste Electrode Modified with Vanadyl(Ⅳ)-Salen Complex[J].Anal Chim Acta,2004,508(1):79-85.
[15] Tan L,Xie Q,Yao S.Electrochemical and Spectroelectrochemical Studies on Pyridoxine Hydrechloride Using a Poly(methylene blue)Modified Electrode[J].Electroanalysis,2004,16:1592-1597.
[16] Vase V D,Srivastava A K.Determination of Pyridoxine Hydrochloride in Pharmaceutical Preparations by Calixarene Based Potentiometric Sensor[J].J Pharm Biomed Anal,2008,47(1):177-182.
[17] Crevillaán A G,Pumera M,González M C,et al.Carbon Nanotube Disposable Detectors in Microchip Capillary Electrophoresis for Water-soluble Vitamin Determination:Analytical Possibilities in Pharmaceutical Quality Control[J].Electrophoresis,2008,29:2997-3004.
[18] Ashok M,Prasad A V S S,Reddy P M,et al.Ru(Ⅲ)-catalyzed Oxidation of Pyridoxine and Albuterol in Pharmaceuticals[J].Spectrochim Acta,2009,72:204-208.
[19] Qu W,Wu K,Hu S.Voltammetric Determination of Pyridoxine(Vitamin B6)by Use of a Chemically-modified Glassy Carbon Electrode[J].J Pharm Biomed Anal,2004,36(3):631-635.
[20] WANG Chunyan,TANG Xiaofeng,TIAN Jian,et al.Determination of Dopamine on a Poly(amino black 10B)/Nafion Modified Electrode[J].Chinese J Anal Chem,2009,37(12):1800-1804(in Chinese).王春燕,唐小风,田坚,等.聚氨基黑10B/Nation修饰电极上多巴胺的检测[J].分析化学,2009,37(12):1800-1804.
[21] Engstrom R C.Electrochemical Pretreatment of Glassy Carbon Electrodes[J].Anal Chem,1982,54:2310-2314.
[22] McCreery R L,Poon M.In Situ Laser Activation of Glassy Carbon Electrodes[J].Anal Chem,1986,58:2745-2750.
[23] Martell A E,Smith R M.Critical Stability Constants[M].New York:Plenum Press,1989,6:478.
[24] YI Qiushi,WAN Qijin,YU Jiuhong,et al.Electrochemical Behaviour of Polymethyl Red Film Modified Electrode and the Voltammetric Determination of Pyridoxal Hydrochloride[J].Chinese J Anal Sci,2001,17(5):379-382(in Chinese).易求实,万其进,喻玖宏,等.聚甲基红膜修饰电极的电化学性质及其对盐酸吡哆辛的伏安测定[J].分析科学学报,2001,17(5):379-382.
[25] Rasmi H,Mohammad-Rezaei R.Flow Injection Amperometric Determination of Pyridoxine at a Prussian Blue Nanoparticle-modified Carbon Ceramic Electrode[J].Electrochim Acta,2010,55(5):1814-1819.
[26] Li X,Zhang Q,Lian H,et al.Separation of Three Water-soluble Vitamins by Poly(dimethylsiloxane)Microchannel Electrophoresis with Electrochemical Detection[J].J Sep Sci,2007,30:2320-2325.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%