本文主要介绍了各种无酶葡萄糖的检测方法.相对于酶法,该方法克服了由于酶本身固有的属性而导致的在固定化过程中不稳定易失活的缺点,具有较好的重现性、稳定性以及抗干扰能力.
参考文献
[1] | Mullen W H,Keedy F H,Churchouse S,et al.Glucose Enzyme Electrode with Extended Linearity[J].Anal Chim Acta,1986,183:59-66. |
[2] | Jonsson G,Gorton L.An Amperometric Glucose Electrode Based on Adsorbed Glucose-Oxidase on Palladium Gold Modified Graphite[J].Anal Lett,1987,20:839-855. |
[3] | Xiao Y,Patolsky F,Katz E,et al."Plugging into Enzymes":Nanowiring of Redox Enzymes by a Gold Nanoparticle[J].Science,2003,299:1877-1881. |
[4] | Park S,Boo H,Chung T D.Electrochemical Non-Enzymatic Glucose Sensors[J].Anal Chim Acta,2006,556:46-57. |
[5] | Vassilyev Y B,Khazova O A,Nikolaeva N N.Kinetics and Mechanism of Glucose Electrooxidation on Different Electrode-Catalysts.Part Ⅰ.Adsorption and Oxidation on Platinum[J].J Electroanal Chem,1985,196:105-125. |
[6] | Nagy L,Nagy G,Hajos P.Copper Electrode Based Ampermetric Detector Cell for Sugar and Organic Acid Measurements[J].Sens Actuators B,2001,76:494-499. |
[7] | Ye J S,Wen Y,Zhang W D,et al.Nonenzymatic Glucose Detection Using Multi-Walled Carbon Nanotube Electrodes[J].Electrochem Commun,2004,6:66-70. |
[8] | LUO Hongxia,SHI Zijin,LI Nanqiang,et al.Investigation on the Electrochemical and Electrocatalytic Behavior of Chemically Modified Electrode of Single Wall Carbon Nanotube Functionalized with Carboxylic Acid Group[J].Chem J Chinese Univ,2000,21:1372-1376(in Chinese).罗红霞,施祖进,李南强,等.羧基化单层碳纳米管修饰电极的电化学表征及其电催化作用[J].高校化学学报,2009,21:1372-1376. |
[9] | Liu P,Hu J.Carbon Nanotube Powder Microelectrodes for Nitrite Detection[J].Sens Actuators B,2002,84:194-199. |
[10] | Zhang W D,Wen Y,Liu S M,et al.Synthesis of Vertically Aligned Carbon Nanotubes on Metal Deposited Quartz Plates[J].Carbon,2002,40:1981-1989. |
[11] | Song Y Y,Zhang D,Gao W,et al.Nonenzymatic Glucose Detection by Using a Three Dimensionally Ordered.Macroporous Platinum Template[J].Chem Eur J,2005,11:2177-2182. |
[12] | Yan J H,Wang K,Xia X H.Hightly Ordered Platinum-Nanotuble Arrays for Amperometric Glucose Sensing[J].Adv Funct Mater,2005,15:803-809. |
[13] | Xu Q,Zhao Y,Zhu J J,et al.Preparation of Functionalized Copper Nanoparticles and Fabrication of a Glucose Sensor[J].Sens Actuators B:Chem,2006,114:379-386. |
[14] | Bai Y,Yang W W,Sun Y,et al.Enzyme-Free Glucose Sensor Based on a Three-Dimensional Gold Film Electrode[J].Sens Actuators B:Chem,2008,134:471-476. |
[15] | Liu Y,Teng H,Hou H Q,et al.Nonenzymatic Glucose Sensor Based on Renewable Electrospun Ni Nanoparticle-Loaded Carbon Nanofiber Paste Electrode[J].Biosens Bioelectron,2009,24:3329-3334. |
[16] | Bai H Y,Han M,Du Y Z,et al.Facile Synthesis of Porous Tubular Palladium Nanostructures and Their Application in a Nonenzymatic Glucose Sensor[J].Chem Commun,2010,46:1739-1741. |
[17] | Pang H,Lu Q Y,Wang J J,et al.Glucose-assisted Synthesis of Copper Micropuzzles and Their Application as Nonenzymatic Glucose Sensors[J].Ghem Commun,2010,46:2010-2012. |
[18] | Holt-Hindle P,Nigro S,Asmussen M,et al.Ammperometric Glucose Sensor Based on Platinum Iridium Nanomaterials[J].Electrochem Commun,2008,10:1438-1441. |
[19] | Yi Q F,Huang W,Yu W Q,et al.Hydrothermal Synthesis of Titanium-Supported Nickel Nanoflakes for Electrochemical Oxidation of Glucose[J].Electroanalysis,2008,20:2016-2022. |
[20] | (O)zcan L,Sahin Y,Türk H.Non-Enzymatic Glucose Biosensor Based on Overoxidized Polypyrrole Nanofiber Electrode Modified with Cobalt(Ⅱ) Phthalocyanine Tetrasulfonate[J].Biosens Bioelectron,2008,24:512-517. |
[21] | Rong L Q,Yang C,Qian Q Y,et al.Study of the Nonenzymatic Glucose Sensor Based on Highly Dispersed Pt Nanoparticles Supported on Carbon Nanotubes[J].Talanta,2007,72:819-824. |
[22] | Jiang L C,Zhang W D.A Highly Sensitive Nonenzymatic Glucose Sensor Based on CuO Nanoparticles-modified Carbon Nanotube Electrode[J].Biosens Bioelectron,2010,25:1402-1407. |
[23] | Li C L,Su Y,Zhang S W,et al.An Improved Sensitivity Nonenzymatic Glucose Biosensor Based on a Cux O Modified Electrode[J].Biosens Bioelectron,2011,26:903-907. |
[24] | Shim J H,Cha A,Lee Y,et al.Nonenzymatic Amperometric Glucose Sensor Based on Nanoporous Gold/Ruthenium Electrode[J].Electroanalysis,2011,23:2057-2062. |
[25] | Bergemann C,Müller-Schulte D,Oster J,et al.Magnetic Ion-Exchange Nano-and Microparticles for Medical,Biochemical and Molecular Biological Applications[J].Magn Magn Mater,1999,194:45-52. |
[26] | Safarik I,Safarikova M.Magnetic Techniques for the Isolation and Purification of Proteins and Peptides[J].Biomagn Res Technol,2004,2:7-10. |
[27] | Brahler M,Georgieva R,Buske N,et al.Magnetite-Loaded Carrier Erythrocytes as Contrast Agents for Magnetic Resonance Imaging[J].Nano Lett,2006,6:2505-2509. |
[28] | De Vries I J,Lesterhuis W J,Barentsz J O,et al.Magnetic Resonance Tracking of Dendritic Cells in Melanoma Patients for Monitoring of Cellular Therapy[J].Nat Biotechnol,2005,23:1407-1413. |
[29] | Denis M C,Mahmood U,Benoist C,et al.Imaging Inflammation of the Pancreatic Islets in Type 1 Diabetes[J].Proc Natl Acad Sci USA,2004,101:12634-12639. |
[30] | Gao L Z,Zhuang J,Nie L,et al.Intrinsic Peroxidase-like Activity of Ferromagnetic Nanoparticles[J].Nat Nanotechnol,2007,2:577-583. |
[31] | Wei H,Wang E K.Fe3O4 Magnetic Nanoparticles as Peroxidase Mimetics and Their Applications in H2O2 and Glucose Detection[J].Anal Chem,2008,80:2250-2254. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%