制备了一种简单的聚谷氨酸修饰玻碳电极的用于检测甲基对硫磷的电化学传感器.并应用循环伏安法研究了甲基对硫磷在该修饰电极上的氧化还原行为;甲基对硫磷的浓度检测采用差分脉冲伏安法,结果表明,甲基对硫磷在5.0×10ˉ7 ~7.5×10ˉ4 mol/L浓度范围与响应电流有良好的线性关系.甲基对硫磷检测限(S/N=3)可达1.0×10ˉ9 mol/L.该法制备的传感器有望应用于实际样品中的甲基对硫磷的检测.
参考文献
[1] | Rico A,G eber-Corr(e)a R,Campos P S,et al.Effect of Parathion-Methyl on Amazonian Fish and Fresh Water Invertebrates:a Comparison of Sensitivity with Temperature Data[J].Arch Environ Contam Oxicol,2010,58(3):765-767. |
[2] | Tankiewicz M,Fenik J,Biziuk M.Determination of Organophosphorus and Organonitrogen Pesticides in Water Samples[J].TrAC Trends Anal Chem,2010,29(9):1050-1063. |
[3] | Zhou Q,Xiao J,Wang W,et al.Determination of Atrazine and Simazine in Environmental Water Samples Using Multiwalled Carbon Nanotubes as the Adsorbents for Preconcentration Prior to High Performance Liquid Chromatography with Diode Array Detector[J].Talanta,2006,68(4):1309-1315. |
[4] | Qu L J,Zhang H,Zhu J H,et al.Rapid Determination of Organophosphorous Pesticides in Leeks by Gas Chromatographytriple Quadrupole Mass Spectrometry[J].Food Chem,2010,122(1):327-332. |
[5] | Sinha S N,Rao M V V,Vasudev K,et al.A Liquid Chromatography Mass Spectrometry-Based Method to Measure Organophosphorous Insecticide,Herbicide and Non-organophosphorous Pesticide in Grape and Apple Samples[J].Food Control,2012,25(2):636-646. |
[6] | Wei Y Y,Li Y,Qu Y H,et al.A Novel Biosensor Based on Photoelectron-Synergistic Catalysis for Flow-Injection Analysis System/Amperometric Detection of Organophosphorous Pesticides[J].Anal Chim Acta,2009,643 (1):13-18. |
[7] | Chen S Z,Huang J,Du D,et al.Methyl Parathion Hydrolase Based Nanocomposite Biosensors for Highly Sensitive andSelective Determination of Methyl Parathion[J].Biosens Bioelectron,2011,26(1):4320-4325. |
[8] | Raghu P,Kumara Swamy B E,Madhusudana Reddy T.Sol-Gel Immobilized Biosensor for the Detection of Organophosphorous Pesticides:A Voltammetric Method[J].Bioelectrochemistry,2012,83 (11):19-24. |
[9] | Wang Y Z,Qiu H X,Hu S Q,et al.A Novel Methyl Parathion Electrochemical Sensor Based on Acetylene Black-Chitosan Composite Film Modified Electrode[J].Sens Actuators B,2010,147 (2):587-592. |
[10] | Wang C Y,You T Y,Tian J.Simultaneous Determination of Hydroquinone and Catechol with Poly(glutamic acid) Modified Electrode[J].AnalChem,2011,39(4):528-533. |
[11] | Liu X,Luo L Q,Ding Y P,et al.Poly-Glutamic Acid Modified Carbon Nanotube-Doped Carbon Paste Electrode for Sensitive Detection of L-Tryptophan[J].Bioelectrochemistry,2011,82(1):38-45. |
[12] | Daniela P Santos,Marcio F Bergamini,Maria Valnice B Zanoni.Voltammetric Sensor for Amoxicillin Determination in Human Urine Using Polyglutamic Acid/glutaraldehyde Film[J].Sens Actuators B,2008,133(2):398-403. |
[13] | Zhang Y Z,Zhang K Y,Ma H Y.Electrochemical DNA Biosensors Based on Gold Nanoparticles/Cysteamine/Poly(glutamic acid) Modified Electrode[J].Am J Biomed Sci,2009,1(2):115-125. |
[14] | Zhang Y,Kang T F,Wan Y W.Gold Nanoparticles-Carbon Nanotubes Modified Sensor for Electrochemical Determination of Organophosphate Pesticides[J].Microchim Acta,2009,165 (10):307-311. |
[15] | Kang T F,Wang F,Lu L P,et al,Methyl Parathion Sensors Based on Gold Nanoparticles and Nation Film Modified Glassy Carbon Electrodes[J].Sens Actuators B,2010,145(1):104-109. |
[16] | Zeng Y B,Yu D J,Yu Y Y,et al.Differential Pulse Voltammetric Determination of Methyl Parathion Based on MultiwalledCarbon Nanotubes-Poly (acrylamide) Nanocomposite Film Modified Electrode[J].J Hazard Mater,2012,217 (5):315-322. |
[17] | Parham H,Rahbar N.Square Wave Voltammetric Determination of Methyl Parathion Using ZrO2-Nanoparticles Modified Carbon Paste Electrode[J].J Hazard Mater,2010,177(1):1077-1084. |
[18] | Santos D P,Zanoni M V B,Bergamini M F,et al.Poly (glutamic Acid) Nanofibre Modified Glassy Carbon Electrode:Characterization by Atomic Force Microscopy,Voltammetry and Electrochemical Impedance[J].Electrochim Acta,2008,53(11):3991-4000. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%