建立了反相高效液相色谱外标法检测荧光增白剂CBS(即CF-351)中N,N-二甲基甲酰胺(DMF)残留量的方法.使用Accurasil C18(150 mm×4.6 mm,5μm)反相液相色谱柱,以甲醇-水为流动相梯度洗脱,流速为1.0mL/min,检测波长为205 nm,柱温为30℃,进样量为5μL.在上述条件下,在DMF质量浓度为0.19~141 mg/L范围内,其峰面积与质量浓度的线性关系良好.在加标水平(用质量分数表示)为0.234 4%和0.467 8%时,回收率为98.4%~107.3%.本方法最低检出限(LOD)为0.019%(质量分数),峰面积的相对标准偏差(RSD)为1.73%.此方法可快速、准确地测定出荧光增白剂CBS中DMF的残留量.
参考文献
[1] | Yang H Q,Yi X,Su J L.Textile Auxiliaries(杨辉琼,易翔,苏娇莲.印染助剂),2005,22(3):21 |
[2] | Chen G M,Yan X B,Li W,et al.Journal of Nanyang Normal University(陈改敏,闫学斌,李雯.等.南阳师范学院学报),2006,5(6):55 |
[3] | Wang M,Xing Z Y,ku B,et al.Qilu Pharmaceutical Affairs (王梅,邢志勇,刘冰,等.齐鲁药事),2006,25(8):478 |
[4] | Ding Y,Fang L.Northwest Pharmaceutical Journal(丁勇,方琳.西北药学杂志),2000,15(6):246 |
[5] | Lu Y F.Chinese Journal of Public Health(鲁雁飞.中国公共卫生),1992,8(7):301 |
[6] | Lu Y F.Journal of Hygiene Research(鲁雁飞.卫生研究),1992,21(3):145 |
[7] | Zhou J K,Wang L S,Zhao R F.Food & Machinery(周建科,王立双,赵瑞峰.食品与机械),2009,25(1):117 |
[8] | Chinese Pharmacopoeia Commission.Pharmacopoeia of People's Republic of China:Part Ⅱ.Beijing:Chemical Industry Press,2005:Appendix 30(国家药典委员会.中华人民共和国药典:二部.北京:化学工业出版社,2005:附录30) |