建立了固相莘取-亲水相互作用色谱/串联质谱同时测定食品中三聚氰胺和三聚氰酸残留量的方法.采用乙腈和水提取试样中残留的三聚氰胺和三聚氰酸,正己烷脱脂,提取液经亲水性健合硅胶和阳离子交换树脂复合填料柱(MCT柱)净化.采用亲水相互作用色谱柱进行分离,质谱采用正、负离子切换模式电离,多反应监测模式检测,同位素内标法定量.三聚氰胺和三聚氰酸在10~2500μg/L范围内呈线性相关,相关系数(γ)均大于0.99,定量限分别为25和50 μg/kg.本方法在动物源性食品、植物源性食品、乳及乳制品等不同样品中的三聚氰胺和三聚氰酸高、中、低3个添加水平的回收率分别在70.0%~129.6%和70.0%~128.6%之间,相对标准偏差分别在1.4%~23.3%和2.8%~18.7%之间.该方法可满足食品中三聚氰胺和三聚氰酸同时定量测定的需要.

参考文献

[1] Dobson R L M,Motlagh S,Quijano M,et al.Toxicol Sci,2008,106(1):251
[2] Li F G,Yao W Q,Tian Y H,et al.Chinese Journal of Chromatography(李锋格,姚伟琴,田延河,等.色谱),2010,28(3):319
[3] GB/T 22288-2008
[4] GB/T 22388-2008
[5] Lou B B,Zhu F C,Hong P,et al.Chinese Journal of Health Laboratory Technology(楼冰冰,祝福春,洪萍,等.中国卫生检验杂志),2009,19(2):296
[6] Ding T,Xu J Z,Li J Z,et al.Chinese Journal of Chromatography(丁涛,徐锦忠,李健忠,等.色谱),2008,26(1):6
[7] GB/T 22400-2008
[8] Wei J,Guo Z M,Shen A J,et al.Chinese Journal of Chromatography(魏杰,郭志谋,沈爱金,等.色谱),2011,29(7):687
[9] Venkatasami G,Sowa J Jr.Anal Chim Acta,2010,665(2):227
[10] Sun H,Wang L,Ai L,et al.Food Control,2010,21(5):686
[11] Cai Q R,Ouyang Y Y,Qian Z J,et al.Chinese Journal of Chromatography(蔡勤仁,欧阳颖瑜,钱振杰,等.色谱),2008,26(3):339
[12] Huang F,Huang X L,Wu H Q,et al.Journal of Instrumental Analytical(黄芳,黄晓兰,吴惠勤,等.分析测试学报),2008,27(3):313
[13] Li A J,Zhang D H,MA S M,et al.Chinese Journal of Analytical Chemistry(李爱军,张代辉,马书民,等分析化学),2008,36(5):699
[14] Mei S B,Hou J,Zhang W G,et al.Chinese Journal of Chromatography(梅少博,侯晋,张文国,等.色谱),2010,28(12):1189
[15] Karbiwnyk C M,Andersen W C,Turnipseed S B,et al.Anal Chim Acta,doi:10.1016/j.aca.2008.08.037
[16] Ibá(n)ez M,Sancho J V,Hernández F.Anal Chim Acta,2009,649(1):91
[17] Li F G,Yao W Q,Su M,et al.Chinese Journal of Chromatography(李锋格,姚伟琴,苏敏,等.色谱),2009,27(2):233
[18] Lu Y P,Fang H W,Hu Y J,et al.Chinese Journal of Analysis Laboratory(卢跃鹏,方慧文,胡筱静,等.分析试验室),2010,29(11):94
[19] Miao H,Fan S,Wu Y N,et al.Chinese Journal of Preventive Medicine(苗虹,范赛,吴永宁,等.中华预防医学杂志),2009,43(5):438
[20] Zhu W X,Yuan P,Yang J Z,et al.Journal of Instrumental Analytical(祝伟霞,袁萍,杨冀州,等.分析测试学报),2008,27(12):1288
[21] Miao H,Fan S,Wu Y N,et al.Biomed Environ Sci,2009,22:87
[22] Luan W.Journal of Instrumental Analytical(栾伟.分析测试学报),2008,27(Suppl):203
[23] Zhang M,Li S,Yu C,et al.JChromatogrB,2010,878(9/10):758
[24] FDA,USA.Laboratory Information Bulletin No.4421,2008
[25] FDA,USA.Laboratory Information Bulletin No.4422.2008