建立了一种可视化的、利用移动中和界面离线富集-毛细管电泳检测电镀水中痕量重金属离子的新方法.在该富集系统中,阳极电解液为2.1 mmol/L HCl-98 mmol/L KCl-痕量重金属离子,阴极电解液为4.0 mmol/LNaOH-96 mmol/L KCl,界面向阴极移动,分离电压为180 V,阴极电解液和阳极电解液的流速均为1 mL/min.富集后凝胶中的金属离子浓度用毛细管电泳检测,标准曲线在实验浓度范围内均有良好的线性关系(r≥0.998 5),预富集倍数达80 ~150倍,Cu(Ⅱ)、Zn(Ⅱ)、Ni(Ⅱ)、Mg(Ⅱ)、Ca(Ⅱ)、Cr(Ⅲ)和Fe(Ⅲ)的检出限分别为0.163、0.256、0.077、0.153、0.203、0.062和0.142 mg/L,均明显低于国家规定标准;日内和日间精密度均小于7.42%.所建方法已成功用于实际电镀废水样品中痕量重金属离子的富集和检测.

参考文献

[1] Bishop P L.Pollution Prevention:Fundamentals and Practice.Boston:McGraw Hill Co.,Inc.,2000
[2] Li Y,Yin X B,Yan X P.Anal Chim Acta,2008,615:105
[3] Shang X H,Zhao Y F,Zhang L,et al.Chinese Journal of Chromatography(尚晓红,赵云峰,张磊,等.色谱),2011,29(7):667
[4] Li F,Wang D D,Yan X P,et al.J Chromatogr A,2005,1081:232
[5] Pang Y H,Liu M Y,Liu S Y,et al.Chinese Journal of Chromatography(庞艳华,刘名扬,刘淑艳,等.色谱),2011,29(10):1027
[6] Li B H,Yan X P.Electrophoresis,2007,28:1393
[7] Zhao Y Q,Zheng J P,Yang M W,et al.Chinese Journal of Chromatography(赵云强,郑进平,杨明伟,等.色谱),2011,29(2):111
[8] Jo S H,Lee S Y,Park K M,et al.J Chromatogr A,2010,1217:7100
[9] Niu L Y,Shen Z G.Chinese Journal of Chromatography(牛立元,沈振国.色谱),2009,27(6):829
[10] Wylie D E,Lu D,Carlson L D,et al.Proc Natl Acad Sci USA,1992,89(9):4104
[11] Tang M H,Tu C Y,Tao Y,et al.Science and Technology of Food Industry(唐美华,屠春燕,陶燕,等.食品工业科技),2011(2):336
[12] Lau H F,Quek N M,Law W S,et al.Electrophoresis,2011,32:1190
[13] Shi M,Gao Q Y,Lu Y C,et al.Journal of China University of Mining & Technology(石美,高庆宇,陆永超,等.中国矿业大学学报),2011,40(2):305
[14] Quirino J P,Kim J B,Terabe S.J Chromatogr A,2002,965:357
[15] Isoo K,Terabe S.Anal Chem,2003,75:6789
[16] Tang A N,Jiang D Q,Yan X P.Anal Chim Acta,2004,507:199
[17] Tan F,Yang B C,Guan Y F.Anal Sci,2005,21:955
[18] Petr J,Gerstmann S,Frank H.J Sep Sci,2006,29:2256
[19] Lopes F S,Coelho L H G,Gutz I G R.Electrophoresis,2011,32:939
[20] Kuban P,Strieglerova L,Gebauer P,et al.Electrophoresis,2011,32:1025
[21] Cao C X.J Chromatogr A,1998,813:153
[22] Cao C X.Acta Chem Scand,1998,52:709
[23] Cao C X,Zhu J H,Liu H,et al.Acta Chem Scand,1999,53:955
[24] Cao C X,Fan L Y,Zhang W.Analyst,2008,133:1139
[25] Fan L Y,Li C J,Zhang W,et al.Electrophoresis,2008,29:3989
[26] Jin J,Shao J,Li S,et al.J Chromatogr A,2009,1216:4913
[27] Zhang W,Chen J F,Fan L Y,et al.Analyst,2010,135:140
[28] Liang H,Chen Y,Tian L J,et al.Electrophoresis,2009,30:3134
[29] Cao C X,Zhou S L,He Y Z,et al.J Chromatogr A,2000,891:337
[30] Yang Q,Fan L Y,Huang S S,et al.Electrophoresis,2011,32:1015
[31] Breadmore M C,Mosher R A,Thormann W.Anal Chem,2006,78:538
[32] Breadmore M C,Thabano J R E,Dawod M,et al.Electrophoresis,2009,30:230
[33] Cao C X,Zhang W,Qin W H,et al.Anal Chem,2005,77:955
[34] Breadmore M C,Dawod M,Quirino J P.Electrophoresis,2011,32:127
[35] Fan Y P,Li S,Fan L Y,et al.Talanta,DOI:10.1016/j.talanta.2012.03.045
[36] GB 25467-2010
[37] GB 25466-2010
[38] GB/T 5749-2006
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%