依据分子印迹技术(MIT)制备的分子印迹聚合物(MIP)颗粒对模板分子及其结构类似物具有特异性识别和选择性吸附作用,同时具有较大的比表面积和快速的传质动力学特性,因而被广泛用作液相色谱固定相和固相萃取材料.将MIP颗粒作为固定相应用于毛细管电色谱(CEC),结合了CEC的快速、高效和MIP的高亲和性、高选择性的特点,成为分析科学领域最具有发展前景的分离技术之一.MIP颗粒在CEC领域有几种不同的应用形式:作为填充材料填充到毛细管柱中;作为嵌入材料嵌入到毛细管柱内部不同基质的骨架中;作为准固定相添加到CEC运行缓冲溶液中.本文综述了近几年MIP颗粒在CEC领域应用的发展,对该领域今后的发展前景进行了展望.
参考文献
[1] | QuP,Lei J P,Ouyang R Z,et al.Anal Chem,2009,81(23):9651 |
[2] | Kitahara K I,Yoshihama I,Hanada T.J Chromatogr A,2010,1217(46):7249 |
[3] | GuJY,Zhang H,Yuan G,et al.J Chromatogr A,2011,1218(45):8150 |
[4] | Prieto A,Schrader S,Bauer C,et al.Anal Chim Acta,2011,685(2):146 |
[5] | Peng Y,Xie Y,Luo J,et al.Anal Chim Acta,2010,674(2):190 |
[6] | Piletska E V,Burns R,Terry L A,et al.J Agric Food Chem,2012,60(1):95 |
[7] | LiL,HeXW,Chen L X,et al.Chem Asian J,2009,4(2):286 |
[8] | GaiQ Q,QuF,LiuZJ,et al.J ChromatogrA,2010,1217(31):5035 |
[9] | Bossi A,Bonini F,Turner A P F,et al.Biosens Bioelectron,2007,22(6):1131 |
[10] | Whitcombe M J,Chianella I,Larcombe L,et al.Chem Soc Rev,2011,40(3):1547 |
[11] | Reimhult K,Yoshimatsu K,Risveden K,et al.Biosens Bioelectron,2008,23(12):1908 |
[12] | Schirhagl R,Lieberzeit P A,Dickert F L.Adv Mater,2010,22(18):2078 |
[13] | Li S J,Ge Y,Turner A P F.Adv Funct Mater,2011,21(6):1194 |
[14] | Wulff G,Liu J Q.Acc Chem Res,2012,45 (2):239 |
[15] | Lettau K,Warsinke A,Katterle M,et al.Angew Chem IntEd,2006,45 (42):6986 |
[16] | Ameli A,Alizadeh N.Anal Biochem,2012,428(2):99 |
[17] | Abdouss M,Asadi E,Azodi-Deilami S,et al.J Mater Sci:Mater Med,2011,22(10):2273 |
[18] | Liu Z S,Zheng C,Yan C,et al.Electrophoresis,2007,28(1/2):127 |
[19] | Huang Y P,Liu Z S,Zheng C,et al.Electrophoresis,2009,30(1):155 |
[20] | Zheng C,Huang Y P,Liu Z S.J Sep Sci,2011,34(16/17):1988 |
[21] | Quaglia M,Lorenzi E D,Sulitzky C,et al.Electrophoresis,2003,24(6):952 |
[22] | Quaglia M,Lorenzi E D,Sulitzky C,et al.Analyst,2001,126(9):1495 |
[23] | Ou J J,LiX,FengS,et al.AnalChem,2007,79(2):639 |
[24] | LiM,Lin X C,Xie Z H.J Chromatogr A,2009,1216(27):5320 |
[25] | Zaidi S A,Cheong W J.Electrophoresis,2009,30 (9):1603 |
[26] | Jang R,KimKH,Zaidi S A,et al.Electrophoresis,2011,32(16):2167 |
[27] | Amini A,Paulsen-Sorman U,Westerlund D.Chromatographia,1999,50 (7/8):497 |
[28] | Spegel P,Schweitz L,Nilsson S.Anal Chem,2003,75(23):6608 |
[29] | Turiel E,Martin-Esteban A.J Sep Sci,2005,28(8):719 |
[30] | Nilsson J,Spegel P,Nilsson S.J Chromatogr B,2004,804(1):3 |
[31] | Huang Y P,Zheng C,Liu Z S.Curr Org Chem,2011,15(11):1863 |
[32] | Poma A,Turner A P F,Piletsky S A.Trends Biotechnol,2010,18(12):629 |
[33] | Nilsson C,Nilsson S.Electrophoresis,2006,27(1):76 |
[34] | Nilsson C,Birnbaum S,Nilsson S.J Chromatogr A,2007,1168(1/2):212 |
[35] | Sellergren B.J Chromatogr A,2001,906 (1/2):227 |
[36] | Lin J M,Nakagama T,Uchiyama K,et al.J Liq Chromatogr Rel Tech,1997,20(10):1489 |
[37] | Lin J M,Nakagama T,Uchiyama K,et al.Biomed Chromatogr,1997,11(5):298 |
[38] | LinJ M,Uchiyama K,Hobo T.Chromatographia,1998,47(11/12):625 |
[39] | Behnke B,Johansson J,Bayer E,et al.Electrophoresis,2000,21(15):3102 |
[40] | Nilsson K,Lindell J,Norrlow O,et al.J Chromatogr A,1994,680(1):57 |
[41] | Lin J M,Nakagama T,Uchiyama K,et al.Chromatographia,1996,43(11/12):585 |
[42] | Chirica G,Remcho V T.Electrophoresis,1999,20 (1):50 |
[43] | Xie R X,Oleschuk R.Anal Chem,2007,79(4):1529 |
[44] | Schmid M G,Koidl J,Freigassner C,et al.Electrophoresis,2004,25(18/19):3195 |
[45] | Dulay M T,Kulkarni R P,Zare R N.Anal Chem,1998,70(23):5103 |
[46] | Gu X,Wang Y,Zhang X M.J Chromatogr A,2005,1072(2):223 |
[47] | Maier N M,Lindner W.Anal Bioanal Chem,2007,389(2):377 |
[48] | Schweitz L,Andersson L I,Nilsson S.Anal Chem,1997,69(6):1179 |
[49] | Zhang Z B,Wu R A,Wu M H,et al.Electrophoresis,2010,31(9):1457 |
[50] | Li H,Yan X H,Ding G S,et al.Journal of Instrumental Analysis(李慧,闫新焕,丁国生,等.分析测试学报),2010,29(6):638 |
[51] | Chen J,Ding G S,Yue C Y,et al.Chinese Journal of Chromatography(陈杰,丁国生,岳春月,等.色谱),2012,30(1):3 |
[52] | Walshe M,Garcia E,Howarth J,et al.Anal Commun,1997,34(4):119 |
[53] | Ye L,Cormack P A G,Mosbach K.Anal Commun,1999,36(2):35 |
[54] | Surugiu I,YeL,Yilmaz E,et al.Analyst,2000,125(1):13 |
[55] | Schweitz L,Spegel P,Nilsson S.Analyst,2000,125 (11):1899 |
[56] | Spegel P,Schweitz L,Nilsson S.Electrophoresis,2001,22(17):3833 |
[57] | De Boer T,Mol R,De Zeeuw R A,et al.Electrophoresis,2002,23(9):1296 |
[58] | Priego-Capote F,Ye L,Shakil S,et al.Anal Chem,2008,80(8):2881 |
[59] | ShiXX,Xu L,Duan H Q,et al.Electrophoresis,2011,32(11):1348 |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%