光学压敏涂料的基质对其压敏性能有着重要作用,将光学压敏涂料的基质分为传统聚合物载体(包括硅胶、溶胶-凝胶膜、硅橡胶等)和新型载体(包括薄层色谱板、阳极氧化铝、聚合物/陶瓷、硅纳米棒、新型聚合物载体等)2个重要发展阶段进行了总结和比较,以此为该类涂料的研究和制备提供一定的参考作用.
参考文献
[1] | KAVANDI J;CALLIS J;GOUTERMAN M et al.Luminescent barometry in wind tunnels[J].Review of Scientific Instruments,1990,61(11):3340-3347. |
[2] | Bell JH.;Hand LA.;Mehta RD.;Schairer ET. .Surface pressure measurements using luminescent coatings [Review][J].Annual Review of Fluid Mechanics,2001(0):155-206. |
[3] | Basu BJ;Thirumurugan A;Dinesh AR;Anandan C;Rajam KS .Optical oxygen sensor coating based on the fluorescence quenching of a new pyrene derivative[J].Sensors and Actuators, B. Chemical,2005(1):15-22. |
[4] | GOUTERMAN M .Oxygen quenching of luminescence of pressure sensitive paint for wind tunnel research[J].Journal of Chemical Education,1997,74(06):697-702. |
[5] | Hubner JP.;Schanze KS.;Ji HF.;Carroll BF. .Pressure-sensitive paint measurements in a shock tube[J].Experiments in Fluids: Experimental Methods and Their Applications to Fluid Flow,2000(1):21-28. |
[6] | Amao Y.;Tabuchi Y.;Yamashita Y.;Kimura K. .Novel optical oxygen sensing material: metalloporphyrin dispersed in fluorinated poly(aryl ether ketone) films[J].European Polymer Journal,2002(4):675-681. |
[7] | MILLS ANDREW;LEPRE ANNE .Controlling the response characteristics of luminescent porphyrin plastic film sensors for oxygen[J].Analytical Chemistry,1997,69(22):4653-4659. |
[8] | DiMarco G.;Lanza M. .Optical solid-state oxygen sensors using metalloporphyrin complexes immobilized in suitable polymeric matrices[J].Sensors and Actuators, B. Chemical,2000(1/2):42-48. |
[9] | Paul Hartmann .Photochemically Induced Energy-Transfer Effects on the Decay Times of Ruthenium Complexes in Polymers[J].Analytical chemistry,2000(13):2828-2834. |
[10] | MARTIN M F CHOI;DAN XIAO .Oxygen-sensitive reversephase optode membrane using silica gel-adsorbed ruthenium(Ⅱ)complex embedded in gelatin film[J].Analytica Chimica Acta,1999,38(02):197-205. |
[11] | K. Eaton;B. Douglas;P. Douglas .Luminescent oxygen sensors: time-resolved studies and modelling of heterogeneous oxygen quenching of luminescence emission from Pt and Pd octaethylporphyrins in thin polymer films[J].Sensors and Actuators, B. Chemical,2004(1):2-12. |
[12] | LIPPITSCH M E;PUSTERHOFER J;LEINER M J P et al.Fibre-optic oxygen sensor with the fluorescence decay time as the information carrier[J].Analytica Chimica Acta,1988,205(1-2):1-6. |
[13] | HE H;FRAATZ R J;LEINER M J P et al.Selection of silicone polymer matrix for optical gas sensing[J].Sensors and Actuators B:Chemical,1995,29(1-3):246-250. |
[14] | JOHN G T;KLIMANT I;WITTMANN C et al.Integrated optical sensing of dissolved oxygen in microtiter plates:a novel tool for microbial cultivation[J].Biotechnology and Bioengineering,2003,81(07):829-836. |
[15] | KIERNAN P;MCDONAGH C;MACCRAITH B D et al.Fibre optic chemical sensors based on evanescent wave interactions in sol gel-derived porous coatings[J].Journal of Sol-Gel Science and Technology,1994,2(1-3):513-517. |
[16] | O'KEEFFE G;MACCRAITH B D;EVOY A K et al.Development of a LED-based phase fluorimetric oxygen sensor using evanescent wave excitation of a sol-gel immobilized dye[J].Sensors and Actuators B:Chemical,1995,29(1-3):226-230. |
[17] | LEE S;OKURA I .Optic sensor for oxygen using a porphyrin doped solgel glass[J].Analyst,1997,122(01):81-84. |
[18] | Zare-Behtash, H;Gongora-Orozco, N;Kontis, K .PSP Visualization Studies on a Convergent Nozzle with an Ejector System[J].Journal of visualization,2009(2):157-163. |
[19] | 张天华,黄俊,韩蕴.基于相移检测的有机改性溶胶-凝胶光学氧敏感膜研究[J].功能材料,2007(01):1-3. |
[20] | 蒋峰芝,许认,王夺元,董兴德,李桂春.气动力压敏漆发光特性研究[J].感光科学与光化学,1999(04):309-315. |
[21] | 蒋峰芝,许认,王夺元,董兴德,李桂春.气动力压敏漆发光氧猝灭影响因素的研究[J].功能材料,2000(01):72-76. |
[22] | Klimant I;Wolfbeis OS .OXYGEN-SENSITIVE LUMINESCENT MATERIALS BASED ON SILICONE-SOLUBLE RUTHENIUM DIIMINE COMPLEXES[J].Analytical chemistry,1995(18):3160-3166. |
[23] | SHARMA A;WOLFBEIS O S .Fiberoptic oxygen sensor based on fluorescence quenching and energy transfer[J].Applied Spectroscopy,1988,42(06):1009-1011. |
[24] | MORENO-BONDI M C;WOLFBEIS O S;MARC J P et al.Oxygen optrode for use in a fiber optic glucose biosensor[J].Analytical Chemistry,1990,62(21):2377-2381. |
[25] | BRIAN D;MACCRAITH;MCDONSGH C M et al.Fibre optic oxygen sensor based on fluorescence quenching of evanescent-wave excited ruthenium complexes in sol-gel derived porous coatings[J].Analyst,1993,118(04):385-388. |
[26] | Hartmann P;Leiner MJP;Lippitsch ME .LUMINESCENCE QUENCHING BEHAVIOR OF AN OXYGEN SENSOR BASED ON A RU(II) COMPLEX DISSOLVED IN POLYSTYRENE[J].Analytical chemistry,1995(1):88-93. |
[27] | BARON A E;DANIELSON J D S;GOUTERMAN M et al.Submillisecond response times of oxygen-quenched luninescent coatings[J].Review of Scientific Instruments,1993,64(12):3394-3402. |
[28] | Y Sakamura;M Matsumoto;T Suzuki .High frame-rate imaging of surface pressure distribution using a porous pressure-sensitive paint[J].Measurement Science & Technology,2005(3):759-765. |
[29] | N. Gongora-Orozco;H. Zare-Behtash;K. Kontis .Global unsteady pressure-sensitive paint measurements of a moving shock wave using thin-layer chromatography[J].Measurement,2010(1):152-155. |
[30] | ASAI K;KANDA H;CUNNINGHAM C T.Surface pressure measurements in a cryogenic wind tunnel by using luminescent coatings[A].Piscataway,NJ,1997:105-114. |
[31] | SAKAUE HIROTAKA;ISHII KEIKO .Optimization of anodized-aluminum pressure-sensitive paint by controlling luminophore concentration[J].Sensors,2010,10(07):6836-6847. |
[32] | KAMEDA M;TEZUKA N;HANGAI T et al.Adsorptive pressure-sensitive coatings on porous anodized aluminum[J].Measurement Science and Technology,2004,15(03):489-500. |
[33] | SCROGGIN A M .Processing and optimization of doped polymer/ceramic composite films for luminescence based pressure and temperature measurement in aerodynamic applications[D].Purdue University,1999. |
[34] | SCROGGIN A M;SLAMOVICH E B;CRAFTON J W.Porous polymer/ceramic composites for luminescence-based temperature and pressure measurement[M].Warrendale,PA,Materials Research Society,1999:347-352. |
[35] | SOUMAGNE-SCHWEYCKART I;M(E)RIENNE M-C;ANCELLE J.Formulation of pressure sensitive paints for unsteady measurements[A].Piscataway,NJ,2001:17-19. |
[36] | GREGORY JW .Unsteady pressure measurements in a turbocharger compressor using porous pressure sensitive paint[D].Purdue University,2002. |
[37] | BENCIC T J;VANDERWAL R.Nanorod material developed for use as an optical sensor platform[A].Cleveland,OH,NASA Glenn Research Center,2005:31-32. |
[38] | GREGORY J W;ASAI K;KAMEDA M et al.A review of pressure-sensitive paint for high-speed and unsteady aerodynamics[J].Proc IMech E,2008,222(02):249-290. |
[39] | MASUDA T;ISOBE E;HIGASHIMURA T .Poly[1-(trimethylsilyl)-1-propyne]:a new high polymer synthesized with transition-metal catalysts and characterized by extremely high gas permeability[J].Journal of the American Chemical Society,1983,105(25):7473-7474. |
[40] | Keisuke Asai;Yutaka Amao;Yoshimi Iijima;Ichiro Okura;Hiroyuki Nishide .Novel Pressure-Sensitive Paint for Cryogenic and Unsteady Wind-Tunnel Testing[J].Journal of thermophysics and heat transfer,2002(1):109-115. |
[41] | TEDUKA N;KAMEDA M;AMAO Y et al.Experimental investigation on time response of pressure-sensitive paint[J].Nippon Koku Uchu Gakkai Nenkai Koenkai Koenshu,2000,31:218-221. |
[42] | Kazukiyo Nagai;Toshio Masuda;Tsutomu Nakagawa;Benny D.Freeman;Ingo Pinnau .Poly[1-(trimethylsilyl)-1-propyne] and related polymers: synthesis, properties and functions[J].Progress in Polymer Science,2001(5):721-798. |
[43] | Hah H.;Sakai T.;Asai K.;Nishide H. .Synthesis of poly(ethynylplatinumporphyrin) and its application as an oxygen pressure-sensitive paint[J].Macromolecular symposia,2003(0):27-35. |
[44] | Puklin E.;Gouin S.;Costin C.;Green E.;Ponomarev S.;Tanji H.;Gouterman M.;Carlson B. .Ideality of pressure-sensitive paint. I. Platinum tetra(pentafluorophenyl)porphine in fluoroacrylic polymer[J].Journal of Applied Polymer Science,2000(13):2795-2804. |
[45] | AMAO Y;MIYASHITA T;OKURA I .Metalloporphyrins immobilized in styrene-trifluoroethylmethacrylate copolymer film as an optical oxygen sensing probe[J].Journal of Porphyrins and Phthalocyanines,2001,5(05):433-438. |
[46] | Amao Y.;Okura I.;Miyashita T. .Optical oxygen detection based an luminescence change of metalloporphyrins immobilized in poly(isobutylmethacrylate-co-trifluoroethylmethacrylate) film[J].Analytica chimica acta,2000(2):167-174. |
[47] | Yutaka Amao;Yuichi Ishikawa;Ichiro Okura .Green luminescent iridium(III) complex immobilized in fluoropolymer film as optical oxygen-sensing material[J].Analytica chimica acta,2001(2):177-182. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%