将负载苯基荧光酮(PF)滤纸纤维用于石墨炉原子吸收光谱法(GFAAs)测定痕量锗的预富集.对锗的富集条件、解吸条件和测定条件进行了研究,在pH=2的含Ge待富集液中,放入负载PF滤纸纤维,在60℃下搅拌60 min,过滤洗涤后,加入5.0 mL浓HNO3微波消解富集锗的负载PF滤纸纤维,得到含Ge清液,以镧作为基体改进剂,涂钨热解石墨管测定.检出限为O.20μg/L,回收率为95.2%-104%,RSD为2.3%-11.8%.结果满意.测定锌精矿和国家标准物质(GSS-6和GSR.5)中的Ge与推荐值吻合.