由于磷存在较严重的多原子离子干扰,使电感耦合等离子体质谱法(ICP-MS)分析钢铁及其合金中痕量磷时受到较大限制.本文采用八极杆碰撞/反应池(ORS)技术,在池内引入惰性气体氦气,通过能量歧视效应来选择分离多原子干扰离子与待测离子,较好地消除了干扰.对相关分析条件进行了全面优化,采用基体匹配并以铑为内标消除基体效应的影响,可实现对钢铁及合金中含量为μg/g级痕量磷的测定.对于浓度范围为0~100 ng/mL的磷,工作曲线的相关系数为0.999 6,方法检出限为0.31 μg/g(3δ,n=11).该方法应用于钢铁及合金标准样品中含量在几十至几百μg/g痕量磷的分析,测定结果与认定值吻合较好,相对标准偏差(RSD)约为5%.
参考文献
[1] | Finkeldei S;Staats G .ICP-MS-A powerful analytical technique for the analysis of traces of Sb,Bi,Pb,Sn and P in steel[J].Fresenius'Journal of Analytical Chemistry,1997,359(4-5):357-360. |
[2] | 臧慕文,刘英,童坚,刘湘生.纯铜、纯镍中磷的ICP-MS法测定[J].分析试验室,2002(06):21-23. |
[3] | Vasilyeva I E;Shabanova E V;Sokolnikova Y V .Selection of internal standard for determination of boron and phosphorus by ICP-MS in siticon photovoltaic materials[J].Journal of Analytical Atomic Spectrometry,1999,14:1519-1521. |
[4] | J. Sabine Becker;Sergei F. Boulyga;Carola Pickhardt;J. Becker;Stefan Buddrus;Michael Przybylski .Determination of phosphorus in small amounts of protein samples by ICP-MS[J].Analytical and bioanalytical chemistry,2003(4):561-566. |
[5] | Houk R S;Lim H B .Atomic emission spectrometry with a reduced-pressure after glow extracted from an inductively coupled plasma[J].Analytical Chemistry,1986,58:3244-3248. |
[6] | 李冰.电感耦合等离子体质谱原理和应用[M].北京:地质出版社,2005 |
[7] | 王小如.电感耦合等离子体质谱实例[M].北京:化学工业出版社,2005 |
[8] | Kozono S;Takahashi S;Haraguchi H .Determination of trace phosphorus in high purity tantalum materials by inductively coupled plasma mass spectrometry subsequent to matrix separation with on-line anion exchange/coprecipitation[J].Analytical and Bioanalytical Chemistry,2003,76(04):542-548. |
[9] | Hughes DM.;Naka H.;Chakrabarti CL.;Gregoire DC. .Determination of trace amounts of phosphorus in high purity iron by electrothermal vaporization inductively coupled plasma mass spectrometry[J].Spectrochimica Acta, Part B. Atomic Spectroscopy,1998(6/8):1079-1085. |
[10] | Hughes DM.;Naka H.;Chakrabarti CL.;Gregoire DC. .THE VAPORIZATION OF PHOSPHORUS COMPOUNDS AND THE USE OF CHEMICAL MODIFIERS FOR THE DETERMINATION OF PHOSPHORUS BY ELECTROTHERMAL VAPORIZATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY[J].Spectrochimica Acta, Part B. Atomic Spectroscopy,1997(4):517-529. |
[11] | 聂玲清,纪红玲,陈英颖,刘小平,王艳萍.基体未分离高分辨电感耦合等离子体质谱法测定钢中痕量元素[J].冶金分析,2007(02):18-23. |
[12] | Yang CH;Jiang SJ .Determination of B, Si, P and S in steels by inductively coupled plasma quadrupole mass spectrometry with dynamic reaction cell[J].Spectrochimica Acta, Part B. Atomic Spectroscopy,2004(9):1389-1394. |
[13] | 胡净宇,王海舟.ICP-MS测定铜锌合金中痕量元素[J].冶金分析,2004(06):1-5. |
[14] | 王明海.ICP-MS法测定金属铝中铜、钛、锌、锰、钴5种痕量杂质元素[J].冶金分析,2004(02):19-22. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%