由于氧化锆陶瓷具有高强度、高韧性和优良的生物相容性使其在生物材料应用领域占有重要地位.近几年来将其用于牙修复方面的报道日益增多.本文总结了氧化锆作为牙修复材料相对于其它修复材料的优点,概括了近年来国内外在氧化锆用于牙修复方面的研究现状,提出了还需要进一步研究的问题,并对其应用前景进行了展望.
参考文献
[1] | Helmer J D;Driskell T D.Research on bioceramics[A].South Carolina(USA):Clemson University,1969 |
[2] | Kosmac T;Oblak C;Jevnikar P .The effect of grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic[J].Dental Materials,1999,15(16):426-433. |
[3] | 斯温·M V.材料科学与技术丛书[A].北京:科学出版社,1998:93. |
[4] | Piconi C;Maccauro G .Zirconia as a ceramic biomaterial.[J].Biomaterials,1999(1):1-25. |
[5] | Jackson M C .Restoration of posterior implants using new ceramic material[J].Journal of Dental Technology,1999,16(07):19-22. |
[6] | Covacci V B;Ruzzese N;Maccauro G et al.In vitro evolution of the utagenic and carcinogen powder of high purity zirconia ceramic[J].Biomaterials,1999,20(04):371-376. |
[7] | 汪大林;刘玲;彭玉田 .牙科陶瓷材料应用研究现状[J].国外医学(生物医学工程分册),1997,20(02):98. |
[8] | 何帅 .牙用氧化锆/玻璃陶瓷复相材料基础研究[D].西安:第四军医大学,2001. |
[9] | Mclaren E A;White S N .Glass-infiltrated zirconia/alumina-based ceramic for crowns and fixed partial dentures[J].Practical Periodontics & Aesthetic Dentistry,1999,11(08):985-994. |
[10] | Kim D.J.;Lee M.H. .Mechanical Properties, Phase Stability, and Biocompatibility of (Y,Nb)-TZP/Al_2O_3 Composite Abutments for Dental Implant[J].Journal of biomedical materials research, Part B. Applied biomaterials,2000(4):438-443. |
[11] | Wolf WD.;Francis LF.;Vaidya KJ. .MECHANICAL PROPERTIES AND FAILURE ANALYSIS OF ALUMINA-GLASS DENTAL COMPOSITES[J].Journal of the American Ceramic Society,1996(7):1769-1776. |
[12] | Drouin J M;Cales B;Chevalier J et al.Fatigue behavior of zirconia hip joint heads:experimental results and finite element analysis[J].Journal of Biomedical Materials Research,1997,34(02):149-155. |
[13] | 汪大林;刘玲 .陶瓷修复体缺损的修补[J].国外医学(生物医学工程分册),2000,23(06):363. |
[14] | Sadoun M;Perelmuter S .Alumina-zirconia machinable abutment for implant-supported single-tooth anterion crowns[J].Practical Periodontics & Aesthetic Dentistry,1997,9(09):1047-1054. |
[15] | Kato K;Shyu C S .Maching of semi-sintered zirconia and its full-sintering for final shape[J].VBI BER,1996,76(12):427-434. |
[16] | Luthardt R;Herold V;Saandkuhl O et al.High-performance ceramics for crowns[J].Deutsche Zahnarztliche Zeitschrift,1998,53(04):280-285. |
[17] | Groot K D;Geesink R;Klein C P A T et al.Elasma sprayed coatings of hydroxyapatite[J].Journal of Biomedical Materials Research,1987,21:1375. |
[18] | Delgado J A;Morcjon L;Martinez S et al.Zirconia-toughened hydroxyapatite ceramic obtained by wet sintering[J].Journal of Materials Science:Materials in Medicine,1999,10(12):715-719. |
[19] | Li J .Bone-implant interface and remaining tissues on the implant surface after push-out test:an SEM observation[J].Biomedical Materials & Engineering,1997,7(06):379-385. |
[20] | 李江,王忠义,张云龙,田杰谟.氧化锆添加剂对牙科用氧化铝玻璃复合体性能的影响[J].实用口腔医学杂志,2000(03):171-174. |
[21] | Kern M;Simon H P;Strub J R .Clinical evaluation of all-ceramic zirconia posts.Apilst study.[Abstract2234][J].Journal of Dental Research,1997,76:293. |
[22] | Kontayas S O;Kern M .All-ceramic posts and cores:The state of the art[J].Quintessence International,1999,30(06):383-392. |
[23] | Hsu H C;Yen S K .Evolution of metal ion release and corrosion resistance of ZrO2 thin coating on the dental Co-Cr alloys[J].Dental Materials,1998,14(05):339-346. |
[24] | Marzzoouk J .Two applications of transmucosal milled cera-mic in implant logy:preliminary clinical examples[J].Quintessence International,1996,27(08):533-547. |
[25] | Kirk P B;Filiaggi M J;Sodhi R N et al.Evaluating sol-gel ceramic thin films for metal implant applications:Ⅲ.In vitro aging of sol-gel-derived zirconia films on Ti-6Al-4V[J].Journal of Biomedical Materials Research,1999,48(04):423-433. |
[26] | Assmann S;Ermrich M;Kvivimann K .Determination of quantitive leucite content impressible ceramics compared to conventional dental[J].Journal of Materials Science:Materials in Medicine,2000,11(12):833-835. |
[27] | Kern M;Stefan M;Wegner .Bonding to zirconia ceramic:adhesion methods and their durability[J].Dental Materials,1998,14:64-71. |
[28] | Heydecke G;Butz F;Strub J R .Fracture strength and survival rate of end odontilly treated maxillaing incisors with approximal cavities after restoration with different post and core systems:an in-itro study[J].Journal of Dentistry,2001,29:427-433. |
[29] | M. Schweiger;M. Frank .Microstructure and properties of a composite system for dental applications composed of glass-ceramics in the SiO2-Li2O-ZrO2-P2O5 system and ZrO2-ceramic (TZP)[J].Journal of Materials Science,1999(18):4563-4572. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%