介绍了医用钛合金的应用前景,分析了其腐蚀机理,并简述了新型医用钛合金及其表面耐蚀性涂层的研究进展.通过加入不同含量的Mo、Nb、Pa、Zr、Ta等元素生成的各种耐蚀性涂层可以改善钛合金的耐蚀性能.

参考文献

[1] 郭天文.口腔科用钛合金和应用[M].北京:人民军医出版社,2005:2.
[2] Long M;Rack HJ .Titanium alloys in total joint replacement--a materials science perspective.[J].Biomaterials,1998(18):1621-1639.
[3] 付涛,张玉梅,李浩,徐可为.羟基磷灰石生物涂层的体外溶解性研究[J].生物医学工程学杂志,2000(04):373-375.
[4] 李世普.生物医用材料导论[M].武汉:武汉工业大学出版社,2000:53.
[5] 张超武;杨海波.生物材料概论[M].北京:化学工业出版社,2006:70.
[6] Semlitdch M;Staub F .Titanium-aluminium-niobium alloy,development for biocompatible,high strength surgical implants[J].Biomedizinische Technik,1985,30:334.
[7] Semlitdch M;Weber H;Streicher R M et al.Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy[J].Biomaterials,1992,13(11):781.
[8] Cheal E;Spector M;Hayes W C .Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty[J].Journal of Orthopaedic Research,1992,10:405.
[9] Ying Long Zhou;Mitsuo Niinomi;Toshikazu Akahori;Hisao Fukui Hiroyuki Toda .Corrosion resistance and biocompatibility of Ti-Ta alloys for biomedical applications[J].Materials Science & Engineering, A. Structural Materials: Properties, Misrostructure and Processing,2005(1/2):28-36.
[10] Oliveira,NT;Guastaldi,AC .Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications.[J].Acta Biomaterialia,2009(1):399-405.
[11] Capela M V;Acciari H A;Capela J M V et al.Repeatability of corrosion parameters for titanium-molybdenum alloys in 0.9% NaCl solution[J].Journal of Alloys and Compounds,2008,465:479.
[12] Kobayashi E.;Doi H.;Yoneyama T.;Hamanaka H.;Wang TJ. .Mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy dental castings[J].Journal of Materials Science. Materials in Medicine,1998(10):567-574.
[13] Choubey A;Balasubramaniam R;Basu B .Effect of replacement of V by Nb and Fe on the electrochemical and corrosion behavior of Ti-6Al-4V in simulated physiological environment[J].Journal of Alloys and Compounds,2004,381:288.
[14] Zheng Y F;Wang B L;Wang J G et al.Corrosion behaviour of Ti-Nb-Sn shape memory alloys in different simulated body solutions[J].Materials Science and Engineering A,2006,438:891.
[15] Asahi Kawashima;Sadao Watanabe;Katsuhiko Asami .XPS Study of Corrosion Behavior of Ti-18Nb-4Sn Shape Memory Alloy in a 0.05 mass percent HCl Solution[J].Materials transactions,2003(7):1405-1411.
[16] Nakagawa M;Matsuya S;Udoh Koich .Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions[J].Dental Materials,2001,20(04):305.
[17] Bonilla FA;Skeldon P;Thompson GE;Piekoszewski J;Chmielewski AG;Sartowska B;Stanislawski J .Corrosion resistant Ti-Pd surface alloys produced by high intensity pulsed plasma beams Part II. Deposition by pulsed implantation doping mode with palladium implantation using a MEVVA source[J].Surface & Coatings Technology,2006(16/17):4684-4692.
[18] Oliveira N T C;Ferreira E A;Duarte L T et al.Corrosion resistance of anodic oxides on the Ti-50Zr and Ti-13Nb-13Zr alloys[J].Electrochimica Acta,2006,51:2068.
[19] Rocher P;Medawar L E;Hornez J C et al.Evidence by spectroscopic ellipsometry of optical property change in pulsed laser deposited NiO films when heated in air at Neel temperature[J].Scripta Materialia,2004,79(4-6):1439.
[20] Shabalovskaya SA .Surface, corrosion and biocompatibility aspects of Nitinol as an implant material.[J].Bio-medical materials and engineering,2002(1):69-109.
[21] Cioffi M;Gilliland D;Ceccone G et al.Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation[J].Acta Biomaterialia,2005,1(06):717.
[22] Figueiraa N;Silvaa T M;Carmezim M J et al.Corrosion behaviour of NiTi alloy[J].Electrochimica Acta,2009,54:921.
[23] Poon R W Y;Ho J P Y;Luk C M Y et al.Improvement on corrosion resistance of NiTi orthopedic materials by carbon plasma immersion ion implantation[J].Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms,2006,242:270.
[24] Liu XM;Wu SL;Chu PK;Chung CY;Chu CL;Chan YL;Yeung KWK;Lu WW;Cheung KMC;Luk KDK .In vitro corrosion behavior of TiN layer produced on orthopedic nickel-titanium shape memory alloy by nitrogen plasma immersion ion implantation using different frequencies[J].Surface & Coatings Technology,2008(11):2463-2466.
[25] Villermaux F;Tabrizian M;Yahia LHocine et al.Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating[J].Biomedical Materials & Engineering,1996,6(04):241.
[26] Komotori Jun;Hisamori Noriyuki;Ohmori Yosuke .The corrosion/wear mechanisms of Ti-6Al-4V alloy for different scratching rates[J].Wear,2007,263:412.
[27] Abd E A M;Maitz M F;El-Hossary F M et al.Surface improvement and biocompatibility of Ti24Al10Nb intermetallic alloy using rf plasma nitriding[J].Applied Surface Science,2007,253:9067.
[28] Yildiz F;Yetimb A F;Alsaran A et al.Wear and corrosion behaviour of various surface treated medical grade titanium alloy in bio-simulated environment[J].Wear,2009,267:695.
[29] H. H. Okhota;O. S. Kalakhan;H. V. Pokhmurs'ka .INFLUENCE OF THE ION IMPLANTATION OF NITROGEN AND BORON AND TiN COATINGS ON THE CORROSION OF VT-6 TITANIUM ALLOY[J].Materials Science,2008(3):405-412.
[30] Thair L;Kamachi M U;Nair K G M et al.Nitrogen ion implantation and in vitro corrosion behavior of as-cast Ti-6Al-7Nb alloy[J].Corrosion Science,2002,44:2439.
[31] Sundararajan T;Mudali U K;Nair K G M et al.Electrochemical studies on nitrogen ion implanted Ti6Al4V alloy[J].Anti-Corrosion Methods and Materials,1998,45(03):162.
[32] Liu XM;Wu SL;Chu PK;Chung CY;Chu CL;Chan YL;Yeung KWK;Lu WW;Cheung KMC;Luk KDK .In vitro corrosion behavior of TiN layer produced on orthopedic nickel-titanium shape memory alloy by nitrogen plasma immersion ion implantation using different frequencies[J].Surface & Coatings Technology,2008(11):2463-2466.
[33] Cui ZD.;Man HC.;Yang XJ. .Characterization of the laser gas nitrided surface of NiTi shape memory alloy[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,2003(0):388-393.
[34] 郭海霞,梁成浩,牟宗信.离子注入TiNi SMA及Co合金耐蚀性与血液相容性研究[J].大连理工大学学报,2002(03):301-305.
[35] Sokolowska, A;Rudnicki, J;Niedzielski, P;Boukowska, A;Boguslawski, G;Wierzchon, T;Mitura, S .TiN-NCD composite coating produced on the Ti6Al4V alloy for medical applications[J].Surface & Coatings Technology,2005(1/4):87-89.
[36] 文峰,黄楠,孙鸿,万国江.等离子浸没离子注入合成TiN/Ti-O梯度薄膜的成分与力学性能[J].机械工程学报,2005(03):155-159.
[37] 王红卫;陈旭;郑昌琼 等.离子注入-直流辉光放电等离子体制备Ti6Al4V-TiN-TiC生物梯度材料[J].苏州大学学报(医学版),1999,15(01):70.
[38] 张幸红,曲伟,张学忠,李亚辉,韩杰才.TiC-Ni梯度功能材料的优化设计[J].材料科学与工艺,2000(01):81-83.
[39] Wang Da-Yung;Chang Yin-Yu;Chang Chi-Lung et al.Deposition of diamond-like carbon films containing metal elements on biomedical Ti alloys[J].Surface and Coatings Technology,2005,200:2175.
[40] Kim Ho-Gun;Ahn Seung-Ho;Kim;Jung-Gu et al.Corrosion performance of diamond-like carbon (DLC)-coated Ti alloy in the simulated body fluid environment[J].Diamond and Related Materials,2005,14:35.
[41] Kim Jung-Gu;Yoo Yun Ha .Aqueous corrosion characteristics of iron aluminides[J].Journal of Biomedical Materials Research,2007,26-28:23.
[42] Cheng Y;Zheng YF .The corrosion behavior and hemocompatibility of TiNi alloys coated with DLC by plasma based ion implantation[J].Surface & Coatings Technology,2006(14/15):4543-4548.
[43] Sui J H;Gao Z Y;Cai W et al.DLC films fabricated by plasma immersion ion implantation and deposition on the NiTi alloys for improving their corrosion resistance and biocompatibility[J].Materials Science and Engineering A,2007,454-455:472.
[44] Wang Da-yung;Chang Yin-Yu;Chang Chi-Lung et al.Deposition of diamond-like carbon films containing metal elements on biomedical Ti alloys[J].Surface and Coatings Technology,2005,200:2175.
[45] Manso M;Ogueta S;Garcia P;Perez Rigueiro J;Jimenez C;Martinez Duart JM;Langlet M .Mechanical and in vitro testing of aerosol-gel deposited titania coatings for biocompatible applications.[J].Biomaterials,2002(2):349-356.
[46] Coreno J;Martinez A;Coreno O et al.Calcium phosphate adsorption as innitial steps of apatite nucleation on sol-gel-prepared titania surface[J].Biomedical Materials,2003,64A:131.
[47] 杜志惠,崔振铎,朱胜利,桑晓明,杨贤金.钛合金阳极氧化膜在Hank's溶液中的腐蚀行为[J].材料热处理学报,2004(06):101-103.
[48] 刘天国,张海金.钛及钛合金阳极氧化[J].航空精密制造技术,2004(04):17-18,22.
[49] 赵树萍;吕双坤.钛合金及其表面处理[M].哈尔滨:哈尔滨工业大学出版社,2003:76.
[50] Lin Chi-Min;Yen Shiow-Kang .Biomimetic growth of apatite on electrolytic TiO2 coatings in simulated body fluid[J].Materials Science and Engineering C,2006,26:54.
[51] Liu JX.;Yang DZ.;Shi F.;Cai YJ. .Sol-gel deposited TiO2 film on NiTi surgical alloy for biocompatibility improvement[J].Thin Solid Films: An International Journal on the Science and Technology of Thin and Thick Films,2003(1/2):225-230.
[52] Dieudonne SC;van den Dolder J;de Ruijter JE;Paldan H;Peltola T;van 't Hof MA;Happonen RP;Jansen JA .Osteoblast differentiation of bone marrow stromal cells cultured on silica gel and sol-gel-derived titania.[J].Biomaterials,2002(14):3041-3051.
[53] 刘敬肖,杨大智.医用NiTi合金表面溶胶-凝胶法制备含磷TiO2薄膜[J].硅酸盐学报,2002(01):45-50.
[54] 洪海云,陈贻炽,朱立群.钛基体上氧化铝膜层的耐高温和耐腐蚀性能研究[J].材料保护,2005(06):18-20.
[55] 吴晓宏,姜兆华,辛世刚,石蕾.钛合金微等离子体氧化表面陶瓷膜耐腐蚀性研究[J].高技术通讯,2002(07):80-82.
[56] Xu J L;Liu F;Yu D Z et al.the corrosion resistance behavior of Al2O3 coating prepared on NiTi alloy by micro-arc oxidation[J].Journal of Alloys and Compounds,2009,472:276.
[57] Song YS;Lee IG;Hong SN;Kim BY;Lee KH;Lee DY .Corrosion properties of plasma-sprayed Al2O3-TiO2 coatings on Ti metal[J].Journal of Materials Science,2006(7):2059-2065.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%