欢迎登录材料期刊网

材料期刊网

高级检索

利用纳米压入测量仪测试了Ti-12Mo-6Zr-2Fe钛合金的硬度和模量.测试表明,Ti-12Mo-6Zr-2Fe钛合金的硬度比Ti-6Al-4V ELI高,而模量比后者低,与常规方法得到的规律一致,表明该方法能很好地表征钛合金的力学特性.对测试过程的分析表明这种方法得到的结果不能与传统方法得到的结果互换,表面状态对测量结果有一定影响.

参考文献

[1] 张泰华,杨业敏.纳米硬度技术的发展和应用[J].力学进展,2002(03):349-364.
[2] Yu. V. Milman;W. Lojkowski;S. I. Chugunova;D. V. Lotsko;I. V. Gridneva;A. Golubenko .Indentation Technique for Determination of Mechanical Behavior of Nanomaterials (Bulk and Coatings)[J].Diffusion and Defect Data. Solid State Data, Part B. Solid State Phenomena,2003(0):55-58.
[3] MILMAN YU V;GALANOV B A;CHUGUNOVA S I .Plasticity characteristic obtained through hardness measurement[J].ACTA METALLURGICA ET MATERIALIA,1993,41(09):2523-2532.
[4] SLIPENYUK A N;MILMAN YU V;DUB S N et al.Peculiarities of the mechanical behavior of metallic glasses investigated by indenation techniques[J].Materials Science Forum,2003,426-432:4513-4518.
[5] ISO 14577-2002.ISO 14577-2002.Metallic Materials-Instrumented Indentation Test for Hardness and Materials Parameters[S].
[6] WANG K K;GUSTAVSON L J;DUMBLETON J H.The characterization of Ti-12Mo-6Zr-2Fe-A new alloy developed for surgical implants[A].,1993:49-60.
[7] 于思荣.生物医学钛合金的研究现状及发展趋势[J].材料科学与工程,2000(02):131.
[8] 张泰华.微/纳米力学测试技术及其应用[M].北京:机械工业出版社,2005
[9] WANG KATHY .The use of titanium for medical applications in the USA[J].Materials Science and Engineering,1996,A213:134-137.