欢迎登录材料期刊网

材料期刊网

高级检索

渗透率是VARTM工艺中的一项关键参数.为了测量VARTM工艺中增强体的渗透率,本文采用数据采集卡和图像采集卡为基础搭建了测试平台,并以Darcy定律的二维形式为理论依据,通过压力传感器和摄像头两种测试手段,获得了渗透率,为进一步客观、准确地获取增强体的渗透率提供了可行、可靠的方法.

参考文献

[1] 祝颖丹,田正刚,王继辉,孟志华.LCM监控技术研究进展[J].玻璃钢/复合材料,2004(05):26-30.
[2] 段跃新,孙玉敏,谭朝元,张佐光.LCM工艺实时监测技术的影响因素[J].复合材料学报,2006(05):89-95.
[3] Thierry Luthy;Paolo Ermanni .Flow Monitoring in Liquid Composite Molding Based on Linear Direct Current Sensing Technique[J].Polymer Composites,2003(2):249-262.
[4] T. Luthy;P. Ermanni .Linear direct current sensing system for flow monitoring in Liquid Composite Moulding[J].Composites, Part A. Applied science and manufacturing,2002(3):385-397.
[5] Akihisa Kikuchi;Evelitsa Higuerey;John Coulter .An experimental investigation of resin flow sensing during molding processes[J].Journal of engineering materials and technology,1995(1):86-93.
[6] T. Luthy;P. Ermanni .Linear direct current sensing system for flow monitoring in Liquid Composite Moulding[J].Composites, Part A. Applied science and manufacturing,2002(3):385-397.
[7] Aurimas Dominauskas;Dirk Heider;John W. Gillespie Jr .Electric time-domain reflectometry sensor for online flow sensing in liquid composite molding processing[J].Composites, Part A. Applied science and manufacturing,2003(1):67-74.
[8] Abraham D;Mcllhagger D.A Comparison of Dielectric Monitoring with Thermal Analysis and Mechanical Testing Techniques for Glass Fiber Epoxy Composite Cure[A].ICAC,1997:149-158.
[9] Mcihagger A;Abraham D;Brown D;Hill B.The Potential of Parallel Plate Dielectric Analysis for the On-line Cure Monitoring of Composite Materials During Resin Transfer Moulding[J].Recent Research Developments in Macromolecules Research,1998(03):105-116.
[10] D. Abraham;R. Mcllhagger .Glass fibre epoxy composite cure monitoring using parallel plate dielectric analysis in comparison with thermal and mechanical testing techniques[J].Composites, Part A. Applied science and manufacturing,1998(7):811-819.
[11] A.Mellhagger;D.Brown;B.Hill .The Development of a Dielectric System for the on-line Cure Monitoring of the Resin Transfer Molding Process[J].Composites Part A:Applied Science and Manufacturing,2000,31:1373-1381.
[12] Sahay,S.K;Kline,R.S.S Hybrid Laster Ultrasonic Based System for Composite Molding[J].ASMEAMD Wave Propagation and Emerging Technologies,1994(188):187-199.
[13] Wang X;Ehlers C;Kissinger C et al.Experimental Investigation of Piezoelectric Wafers in Monitoring the Resin Transfer Molding Process[J].Smart Materials and Structures,1998,7(01):121-127.
[14] K Ken Han;C William Lee;Brain P Rice.Measurements of the permeability of fiber perform and application[J].Computer Science and Technology,2000(60):2435-2441.
[15] J. R. Weitzenbock;R. A. Shenoi;P. A. Wilson .Radial flow permeability measurement. part A: theory[J].Composites, Part A. Applied science and manufacturing,1999(6):781-796.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%