设计制作了普通钢筋混凝土受压短柱试件,分成5组进行试验,每组的倒角半径分别为0、10mm、30mm、50mm、70mm.每组又分别按照未加固和粘贴不同层数的FRP进行分类,试验在500T的液压试验机上进行.试验结果表明,倒角半径的大小和FRP布粘贴层数能均影响混凝土柱的强度和延性,具体表现在当倒角半径和纤维布层数在合理范围内时能提高其强度和延性,当二者过大时,不论其强度和延性都会降低,且表现为脆性的剥离破坏.
参考文献
[1] | 王文炜.FRP加固混凝土结构技术及应用[M].北京:中国建筑工业出版社,2007 |
[2] | Mirmiran A;Shahawy M;Samaan M;El Echary H .Effect of columnparameters on FRP-confined concrete[J].Journal of Composites for Construction ASCE,1998,2(04):175-185. |
[3] | 朱成九,朱爱华,卜少磊.碳纤维加固钢筋砼柱承载力的影响因素研究[J].玻璃钢/复合材料,2010(05):3-6. |
[4] | A. Hosseini;Ali R. Khaloo;S. Fadaee .Seismic performance of high-strength concrete square columns confined with carbon fiber reinforced polymers (CFRPs)[J].Canadian Journal of Civil Engineering,2005(3):569-578. |
[5] | Pessiki S;Pieroni A .Axial load behavior of large-scale spirally reinforced high-strength concrete columns[J].ACI Structural Journal,1997,94(03):304-314. |
[6] | Ye LP;Zhang K;Zhao SH;Feng P .Experimental study on seismic strengthening of RC columns with wrapped CFRP sheets[J].Construction and Building Materials,2003,17(6-7):499-506. |
[7] | Lam L;Teng JG.Design-oriented stress-strain model for FRP-confined concrete[J].Construction and Building Materials,2003(17):471-489. |
[8] | 杨志刚.FRP加固圆形混凝土桥柱的轴压强度模型研究[J].玻璃钢/复合材料,2008(01):30-34. |
[9] | 杨志刚,李晓霞.FRP加固轴压混凝土矩形截面柱的承载力计算[J].山东理工大学学报(自然科学版),2009(06):61-65. |
[10] | 张海昆,童谷生,吴秋兰.BFRP约束方形混凝土柱轴心受压强度模型[J].玻璃钢/复合材料,2010(02):71-74. |
[11] | Wu YF;Tao L;Oehlers DJ .Fundamental principles that govern retrofittng of reinforced concrete columns by steel and FRP jacketing[J].Advances in Structural Engineering,2006,9(04):507-533. |
[12] | 王双剑,王元丰.FRP约束混凝土轴心受压短柱承载力计算分析[J].玻璃钢/复合材料,2004(03):16-18,15. |
[13] | 杨志刚.FRP加固混凝土偏心受压柱力学性能的试验研究[J].郑州大学学报(工学版),2010(05):86-89. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%