高级检索

在相同的光亮镀镍液中分别加入浓度依次递增的铜、锌、铁、铬、铜的标准溶液。用原子吸收光谱法连续测定镀液中铜、锌、铁、铬、铅杂质的含量,优选出最佳的仪器工作条件,讨论了共存元素的干扰及消除。该方法简单,准确度和精密度高,具有使用价值。

Increasing amount of copper, zinc, iron, chromium and leadstandard solutions were separately added in the same nickel plating baths, subsequently, copper, zinc, iron, chromium and lead impurities were continuously determined by atomic absorption spectrometry. Operating parameters of the analytical apparatus were optimized. Interference of coexisting elements was discussed. This method is simple, accurate, and has good application value.

参考文献

[1] 国家机械工业委员会技术工人教育研究中心.电镀工[M].北京:高等教育出版社,1988:56.
[2] 川崎元雄;小西三郎;徐清发.实用电镀[M].北京:机械工业出版社,1985:236-239.
[3] 杨德俊.络合滴定的理论和应用[M].北京:国防工业出版社,1986:183.
[4] 谢德尔;李连仲.微量金属比色法[M].北京:地质出版社,1986:241.
上一张 下一张