根据超声波在多层介质中的透射模型,分析介质层厚度变化对声压透射率及衰减的影响趋势.结合钢/环氧树脂/铝粘接结构粘接质量的超声检测结果,分析粘接层厚度的微小变化对粘接质量超声检测的影响.理论分析与实验结果均表明,粘接层厚度的微小变化对检测结果能够产生较大影响.
参考文献
[1] | 李家伟.无损检测手册[M].北京:机械工业出版社,2002:995-1006. |
[2] | Akker S.;Arman J. .ULTRASONIC INVESTIGATION ON PLANE INTERFACES BETWEEN POLYMERS[J].Ultrasonics,1997(4):287-295. |
[3] | Dorothee Callens;Christian Bruneel;Jamal Assaad .Matching ultrasonic transducer using two matching layers where one of them is glue[J].NDT & E international: Independent nondestructive testing and evaluation,2004(8):591-596. |
[4] | Goglio L.;Rossetto M. .Ultrasonic testing of anaerobic bonded joints[J].Ultrasonics,2002(1/8):205-210. |
[5] | Adams R D;Drinkwater B W .Nondestructive testing of adhesively-bonded joints[J].NDT & E International,1997,30(02):93-98. |
[6] | R E Challis;R J Freemantle;J D H White;G P Wilkinson .Ultrasonic compression wave NDT of adhered metal lap joints of uncertain dimensions[J].Insight: Non-Destructive Testing and Condition Monitoring,1995(12):954-963. |
[7] | 李明轩.粘接质量超声检测研究[J].应用声学,2002(01):7-12. |
[8] | 王召巴,金永.复合材料多界面脱粘超声检测技术[J].太原师范学院学报(自然科学版),2003(01):45-47. |