从连铸喷雾冷却强度的控制因素入手,建立了冷却强度与水流密度、冲击速度、雾滴尺寸间的关系式.通过测定气水比对上述参数的影响,进而利用该关系式来计算冷却强度.结果表明,气水喷雾冷却过程存在最佳气水比值,但最佳气水比不是固定不变的,它随着水压的增加而减小.最佳气水比的确定对降低连铸二冷能耗具有重要的意义.

参考文献

[1] Deb S;Yao S C .Analysis on Film Boling Heat Transfer of Impacting Spray[J].International Journal of Heat and Mass Transfer,1989,32(11):2099-2112.
[2] 者江;孙晗;李现昌 等.水喷射淬冷高温壁面的传热实验研究[J].工程热物理学报,1997,18(05):629-633.
[3] Moriyama A .Heat Transfer from Hot Steel Surface to a Water Droplet[J].Transactions of the Iron and Steel Institute of Japan,1974,14:285-289.
[4] Choi K J;Yao S C .Mechanisms of Film Boiling Heat Transfer of Normally Impacting Spray[J].International Journal of Heat and Mass Transfer,1987,30(02):311-318.
[5] Brimacombe J K;Agarwal P K;Baptista L A .Spray Cooling in the Continuous Casting of Steel[J].Steel Proc,1980,63:235-252.
[6] Ian Stewart;John D. Massingham;Jerry J. Hagers .Heat transfer coefficient effects on spray cooling[J].Iron and Steel Engineer,1996(7):17-23.