混凝土中钢筋的腐蚀是混凝土结构破坏和修复的主要原因之一,钢筋腐蚀速率的监测和腐蚀状况的判定可以为钢筋混凝土结构的剩余载荷和结构的耐久性提供基础数据.本文叙述了混凝土中钢筋腐蚀的监测技术,包括7种基于电化学基础的测定瞬时腐蚀速率的方法和3种物理方法,给出了测定电位(或电位图)、线性极化、电化学噪音、宏观电池电流、脉冲电流、电化学阻抗谱、恒电量方法的原理、装置和实施方法.同时简单介绍了利用电阻探针法、光纤传导方法、微波反射法测定腐蚀速率和其他腐蚀相关参数(电阻率、pH、C1-)的测定方法.

参考文献

[1] Elsener B .Half-cell potential mapping to assess repair work on RC structure[J].Construction and Building Materials,2001,15:133-139.
[2] Dubravka Bjegovic;Dunja Mikulic;Dalibor ekulic .Non-destructive corrosion rate monitoring for reinforced concrete structures[DB/OL].http://www.ndt.net/article/wcndt00/general/aipnd.htm
[3] BS7361-1991 Cathodic Protection Part I . Code of Practice for Land and Marine Applications[S].
[4] [EB/OL].http://www.force.dk/gb/default.htm
[5] Digested from R G .Kelly's lecture presented to Qingdao Branch[R].LSMRI,2001.
[6] Ralph Baessler et al.Proceedings of SPIE[R].The International Society for Optical Engineering,V3988,2000.
[7] Law D W;Millard S G;Bungey J H.Linear polarisation resistance measurements using a potentiostatically controlled guard ring[J].NDT & E International,2000:15-21.
[8] D. W. LAW;S. G. MILLARD;J. H. BUNGEY .Use of galvanostatic pulse measurements on active reinforcing steel in concrete to assess corrosion rates[J].British Corrosion Journal,2001(1):75-80.
[9] Law D W;Millard S G;Bungey J H .Effect of electrode orientation on linear polarization measurements using sensor controlled guard ring[J].British Corrosion Journal,2000,35(02):136-140.
[10] 吴建华;刘光洲;于辉 等.海洋微生物腐蚀的电化学研究方法[J].腐蚀与防护,1999,20(05):235.
[11] Morlidge J R.Electrochemical techniques for the detection of concrete corrosion inhibitors under simulated pore solution conditions[A].,2000
[12] 赵永韬,吴建华,赵常就.评价混凝土中钢筋腐蚀的恒电量技术[J].电化学,2001(03):258-266.
[13] 赵永韬,刘昌飞,高晓健,吴建华,林昌应,王朝臣.电化学方法检测混凝土横梁中高强钢丝的腐蚀[J].中国腐蚀与防护学报,2003(06):362-366.
[14] G. K. Glass;A. M. Hassanein;N. R. Buenfeld .Obtaining impedance information on the steel-concrete interface[J].Corrosion: The Journal of Science and Engineering,1998(11):887-897.
[15] Alvarez R.Frequency domain transform and the coulostatic technique[A].Houston,1998
[16] Rodriguez P et al.Use of the coulostatic method for measuring corrosion rates of embedded metal in concrete[J].Magazine of Concrete Research,1994(46):91.
[17] Vladimir Zivica .Utilisation of electrical resitance method for the evaluation of the state of steel reinforcement in concrete and the rate of its corrosion[J].Construction and Building Materials,2000(6/7):351-358.
[18] Li X M;Chen W M;Zhu Y et al.Monitoring the corrosion of steel in reinforced concrete using optical waveguide methods[J].Proceedings of Spie,2000,3986:172-179.
[19] Cairong Hu;Aaron Benally;Tobias Case et al.Influence of chloride in mortar made of portland cement types Ⅱ Ⅲ and V on the near-field microwave reflection properties[J].Proceedings of SPIE,2000,4129:31-38.
[20] Polder Bob B .Test methods for on site measurement of resistivity of concrete-a RILEM TC-154 technical recommendation[J].Construction and Building Materials,2001,15:125-131.
[21] Rengaswamy Srinivasan et al.Embedded micro-sensor for monitoring pH in concrete structure[J].Proceedings of Spie,2000,3988:40-44.
[22] Kelly R G;Jones Stephen H.Development of an embeddable microinstrument for corrosivity monitoring in concrete[C].PB99-160210