采用动电位极化曲线测试法研究了温度、通气条件和pH值对X70管线钢在NS4溶液和0.5 mol/L Na2CO3+1 mol/L NaHCO3溶液中的电化学极化行为的影响,并用慢应变速率试验(SSRT)研究了X70管线钢在这些溶液中的应力腐蚀破裂(SCC)敏感性.结果表明,X70管线钢在NS4溶液中不出现活化-钝化转变区,随外加电位负移, SCC敏感性增加,表现出氢致破裂(HIC)的特征;在0.5 mol/L Na2CO3+1 mol/L NaHCO3高pH值溶液中出现活化-钝化转变区,在阴极极化区,也表现出氢致破裂(HIC)的特征,但在阳极极化区,发生的是阳极溶解型应力腐蚀破裂(ADSCC).

参考文献

[1] Kentish P J .Gas pipeline failures:Australian experience[J].British Corrosion Journal,1985,20(03):139-146.
[2] National Energy Board (NEB),Public inquiry concerning stress corrosion cracking on canadian oil and gas pipelines[R].NEB Report Mh-2-95,Calgary,AB,Canada,1996.
[3] King F;Boven G V;Jack T.Predicting the growth of low-and high pH SCC on gas transmission pipelines based on operating conditions[A].Houston:NACE international,2003:127-155.
[4] J A Beavers;Carolyn L Durr;Burke S Delanty.High-pH SCC:temperature and potential dependence for cracking in field environments[A].,1998
[5] E.A. Charles;R.N. Parkins .Generation of Stress Corrosion Cracking Environments at Pipeline Surfaces[J].Corrosion: The Journal of Science and Engineering,1995(7):518-527.
[6] Parkins R N .Predictive approaches to stress corrosion cracking failure[J].Corrosion Science,1980,20(05):151-157.
[7] Sutcliffe J M;Fessler R R;Boyd W K et al.Stress corrosion cracking of carbon steel in carbonate solutions[J].Corrosion,1972,28(08):313-320.