研究了在改性注氧隔离(SIMOX)材料上制备的具有环栅和H型栅结构的部分耗尽NMOS晶体管在三种不同偏置状态的总剂量辐照效应.实验表明在10keV的X-射线总剂量辐照下,器件的背栅、正栅阈值电压负向漂移和漏电流都控制在较小的水平;在2Mrad(SiO2)的辐照下仍能正常工作.研究证实了无论哪种栅结构,对于背栅,PG均为最劣偏置,其次是OFF偏置,而ON偏置下器件受辐照的影响最小;而对于正栅,ON均为最劣偏置.通过拟合计算出了绝缘埋层(BOX,即埋氧)中的饱和净正电荷密度Not和空穴俘获分数α.
参考文献
[1] | Schwank J.R.;Shaneyfelt M.R. .Correlation between Co-60 and X-ray radiation-induced charge buildup in silicon-on-insulator buried oxides[J].IEEE Transactions on Nuclear Science,2000(6):2175-2182. |
[2] | J.R. Schwank;D.M. Fleetwood;H.D. Xiong;M.R. Shaneyfelt;B.L. Draper .Generation of metastable electron traps in the near interfacial region of SOI buried oxides by ion implantation and their effect on device properties[J].Microelectronic engineering,2004(1/4):362-366. |
[3] | Flament O.;Torres A.;Ferlet-Cavrois V. .Bias dependence of FD transistor response to total dose irradiation[J].IEEE Transactions on Nuclear Science,2003(6):2316-2321. |
[4] | Liu S.T.;Balster S. .Worst case total dose radiation response of 0.35 /spl mu/m SOI CMOSFETs[J].IEEE Transactions on Nuclear Science,1999(6):1817-1823. |
[5] | Ferlet-Cavrois V.;Colladant T. .Worst-case bias during total dose irradiation of SOI transistors[J].IEEE Transactions on Nuclear Science,2000(6):2183-2188. |
[6] | Jean-Pierre Colinge.Silicon-on-insulator technology:materials to VLSI[M].Boston:Kluwer Academic Publishers,2000 |
[7] | Nicklaw CJ.;Pantelides ST.;Fleetwood DM.;Schrimpf RD. Galloway KF.;Wittig JE.;Howard BM.;Taw E.;McNeil WH.;Conley JF.;Pagey MP. .Defects and nanocrystals generated by Si implantation into a-SiO2[J].IEEE Transactions on Nuclear Science,2000(6 Pt.3):2269-2275. |