研究了太空站水的总循环开发中EDI膜堆电流、进水的总氨浓度、进水流量等因素对EDI去除氨的影响,并对各影响因素进行了解释.实验结果显示:在氨进水质量浓度高达208.3 mg/L的情况下,出水总氨的质量浓度为0.072 mg/L,EDI对氨的去除率为99.97%.
参考文献
[1] | Kunin R;Myers R J.Ionexchangeresionous[M].New York:John Wiley & Sons,1950:109. |
[2] | Wen R M;Fong P H .UsingROandEDIaseconomicpurifierforhospitalsupply[J].Desalination and Water Reuse,2001,11(01):22-29. |
[3] | Ganzi G C;Parise P.TheproductionofpharmaceuticalgradesofwaterusingcontinuousdenominationPost-ReverseOsmosis[J].Journal of Parenteral and Enteral Nutrition,1990:231-241. |
[4] | DAVID H P.Electrodeionizationinpharmaceuticalwatertreatment[J].Pharmaceutical Technology North America,2002(07):36-42. |
[5] | Spiegl E F;Thompson P M;Helden D J et al.Investigationofanelectrodeionizationsystemfortheremovaloflowconcentrationsofammoniumions[J].Desalination,1999,123:85-92. |
[6] | Laktionov E V;Pismenskava N D;Nikonenko V V.Methodofelectrodialysisstacktestingwiththefeedsolutionconcentrationregulation[J].Desalination,2002:101-116. |
[7] | Shaposhnik VA.;Kesore K. .AN EARLY HISTORY OF ELECTRODIALYSIS WITH PERMSELECTIVE MEMBRANES[J].Journal of Membrane Science,1997(1/2):35-39. |
[8] | J P van der Hoek;Rijnbende D O;Lokin C J A.Electrodialysisasanalternativeforreverseosmosisinanintegratedmembranesystem[J].Desalination,1998:159-172. |
[9] | MAVROV V;Chmiel H;Heitele B.Desalinationofsurfacewatertoindustrialwaterwithlowerimpactontheenvironment(Ⅰ)Newtechnologicalconcept[J].Desalination,1996:159-166. |
[10] | Kesore K.;Shaposhnik VA.;Janowski F. .HIGHLY EFFECTIVE ELECTRODIALYSIS FOR SELECTIVE ELIMINATION OF NITRATES FROM DRINKING WATER[J].Journal of Membrane Science,1997(1):17-24. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%