进行中试实验考察了浸没式超滤膜处理地表水的除污染效果.实验结果表明:膜出水的浊度恒低于0.10 NTU;膜出水的COD_(Mn)值为2.34~3.12 mg/L;膜出水中大于2μm的颗粒总数为11~20个/100 mL;膜出水中未检测出细菌;短周期内的气水反冲洗并排空,可以使膜运行压力在一定程度上得以恢复.
The effectiveness of surface water treatment by immersed UF membrane are investigated through pilot studies.The experimental results show that the turbidity of membrane effluent is below 0.10 NTU; the COD_(Mn) value is 2.34~3.12 mg·L~(-1) ; the number of particles bigger than 2 μm is 11~20 counts per 100 mL; bacterial are un-determined in the membrane effluent.Backwashing with air and water in short period and excluding water empty can resume the membrane running pressure at a certain extent.
参考文献
[1] | Diana M;Mike B.The role of particle count analyzers as an online integrity tool for immersed membrane plants[A].Dallas Texas,1998:37-40. |
[2] | Pierre C;Diana M;Christian C et al.Immersed membrane filtration for the production of drinking water:case studies[J].Desalination,1998,117:181-188. |
[3] | 许振良.膜法水处理技术[M].北京:化学工业出版社,2001:37-40. |
[4] | Jacagelo J G;Adham S S;Laine J M .Mechanism of cryptosporidium,giadia and MS2 virus removal by MF and UF[J].Journal of the American Water Works Association,1995,88(09):107-121. |
[5] | Samer S. Adham;Joseph G. Jacangelo;Jean-Michel Laine .Characteristics and costs of MF and UF plants[J].Journal - American Water Works Association,1996(5):22-31. |
[6] | 刘忠洲,续曙光,李锁定.微滤、超滤过程中的膜污染与清洗[J].水处理技术,1997(04):187. |