采用反渗透膜分离技术对PVC离心母液进行试验,研究了不同进膜压力对膜通量、渗透液电导的影响.在确定了压力参数后.分析了运行时间对膜通量、渗透液电导、COD的影响.试验结果表明.第一次通过RO膜的渗透液电导为42.3 μs;在进膜压力为1.0 MPa,膜设备运行30 min情况下.第二次通过RO膜的渗透液电导为7.37 μs,COD接近于0.出水达到排放标准.经进一步处理可回用于生产.
参考文献
[1] | 伍桂松 .我国聚氯乙烯市场分析及预测[J].化工技术经济,2000,18(05):20-22. |
[2] | C. Jaksland;E. Rasmussen;T. Rohde .A new technology for treatment of PVC waste[J].Waste Management,2000(5/6):463-467. |
[3] | 刘岭梅.悬浮聚氯乙烯工程技术进展[J].化工生产与技术,1999(01):33-35. |
[4] | Carroll W F Jr;Berger T C;Borrelli F E et al.Characterization of emissions of dioxins and furans from ethylene dichloride(EDC),vinyl chloride(VCM)and polyvinylchloride(PVC)manufacturing facilities in the United States.I.Resin,treated wastewater,and ethylene dichloride[J].Chemosphere,1998,37(9-12):1957-1972. |
[5] | Liu J Q;Xu Z L;Li X H et al.An improved method to prepare high separation performance PA/PVDF hollow fiber composite NF membranes[J].Separation and Purification Technology,2007,50:53-60. |
[6] | GB11914-89水质化学需氧量的测定重铬酸钾法[S].北京:中国环境科学出版社,2000. |