结合近年来国内外的文献资料,对变频电机匝间绝缘过早破坏机理进行了系统的阐述.变频电机的匝间电压特性与普通电机有着显著的不同,由此引起的局部放电是导致匝间绝缘快速老化的根本原因,而由局部放电产生的电子轰击、臭氧氧化等作用直接造成了匝绝缘的过早破坏.提高变频电机使用寿命的方法之一就是提高绝缘材料高温条件下的耐局部放电能力,即提高绝缘材料在较高温度下的耐臭氧侵蚀能力和耐空间电荷的破坏能力.

参考文献

[1] 陆宝琦.交流变频电机的绝缘[J].绝缘材料,2001(03):29-34.
[2] Oliver J.A.;Stone G.C. .Implications for the application of adjustable speed drive electronics to motor stator winding insulation[J].IEEE Electrical Insulation Magazine,1995(4):32-36.
[3] A H Bonnett.Analysis of the impact of pulse - width modulated inverter voltage waveforms on A C induction motors[A].,1994:68-75.
[4] R Rhudy;E L Owen;D K Sharma.Voltage distribution among the coils and turns of a form wound AC rotating machine exposed to impulse voltage[A].,1985:109-114.
[5] Yifan Tang .Analysis of steep-fronted voltage distribution and turn insulation failure in inverter-fed form-wound AC motor[J].IEEE Transactions on Industry Applications,1998(5):1088-1096.
[6] T Lebey.A theoretical approach of partial discharges under square voltage wave forms[A].Virginia, USA,1998:257-260.
[7] Weijun Yin .Failure mechanism of winding insulations in inverter-fed motors[J].IEEE Electrical Insulation Magazine,1997(6):18-23.
[8] M Kaufhold;H Auinger;M Berth.Electrial stress and failure mechanism of the winding insulation in PWMInverter-fed low voltage induction motors[J].IEEE Transactions on Industrial Electronics,2000(02):396-402.
[9] Kaufhold M.;Borner G. .Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters[J].IEEE Electrical Insulation Magazine,1996(5):9-16.
[10] A H Bonnet.Comparison between insulation system available for PWM-inverter-fed motors[J].IEEE Transactions on Industry Applications,1997(05):1331-1334.
[11] D H Hwang.Analysis of insulation characteristics of PWM inverter-fed industrial motors[A].Pusan, Korea,2001:477-481.
[12] D H Hwang.Analysis of insulation characteristics of low-voltage induction motors driven by IGBT PWM inverters[A].Anaheim, USA,2000:17-20.
[13] Greg Stone;Steve Campbell;Serge Tetreault .Inverter-fed drives: which motor stators are at risk ?[J].IEEE industry applications magazine,2000(5):17-22.
[14] C Lanier.A novel technique for the determination of relative corona activity within inverter-duty motor insulation systems using steep-fronted voltage pulse[A].Arlington,1998:229-232.
[15] C Hudon;J N Seguin;N Amyot.Turn insulation aging of motors exposed to fast pulses of invetter drives[M].Elect. Insul. Conf., Chicago USA,1997:413-417.
[16] D Fabiani;G C Montanari;F Palmieri.Space charge measurements on enameled wires for electrical windings[M].CWIEME '01, Berlin, Germany,2001
[17] J P Bellomo.Electrical aging of stator insulation of low voltage rotating machines supplied by inverters[A].,1996:210-213.
[18] W Yin;K Bultemeier;D Barta.Critical factors for early failure of magnet wires in inverter-fed motors[A].Annual Report,1995:258-261.
[19] N Foulon;J P Lucas;G Barre.Investigation of the failure mechanism of insulation subject to repetive fast voltage surges[A].,1997:401-406.
[20] Wood S E;Greenwood D;Compton B.Instrumentation of inverter-fed motors for hazardous atmospheres. instrumentation of rotating electrical machines[J].IEEE Colloquium on,1991(02):1-5.
[21] Weijun Yin .Failure mechanism of winding insulations in inverter-fed motors[J].IEEE Electrical Insulation Magazine,1997(6):18-23.
[22] Steven Boggs;John Densly;Jinbo Kuang.Surge-induced temperature rise in water containing defects in XLPE: mechanism for conversion of water trees to electrical trees[A].Electr. Insul.Dielectr. Phen,1996:311-314.
[23] Jinbo Kuang;Steven Boggs.Thermal-electric field distribution around a defect in polyethylene[A].Symposium Electr, Insul,1996:175-178.
[24] R J Beekman;J J Harber;S J Wentz.Studies on magnet wire degradation with inverter driven motors[A].,1997:383-387.