介绍了支柱绝缘子(套管)覆冰的交直流闪络特性和冲击电压闪络特性的研究情况,分析了影响覆冰闪络电压的各种因素,对支柱绝缘子(套管)覆冰闪络特性的研究进行分析与总结,并提出今后研究的方向.

参考文献

[1] 蒋兴良;易辉.输电线路覆冰及防护[M].北京:中国电力出版社,2002
[2] 孙才新;司马文霞;舒立春.大气环境与电气外绝缘[M].北京:中国电力出版社,2002
[3] Charneski M D;Gaibrois G L;Whitney B F .Flashover Test of Artificially Iced Insualtors[J].IEEE Transactions on Power Apparatus and Systems,1982,PAS-101(08):2429-2433.
[4] Farzaneh M.;Drapeau J.F. .AC flashover performance of insulators covered with artificial ice[J].IEEE Transactions on Power Delivery,1995(2):1038-1051.
[5] Li Y;Farzaneh M;Zhang J.Critical Flashover Voltage of Short HV Insulator Covered with Ice at Low Atmospheric Pressure[A].北京,1998:520-523.
[6] Drapeau J F;Farzaneh M;Roy M.An Experimental Study of Flashover Performance of Various Post Insulators Under Icing Conditions[A].Victoria,Canada,2000:359-364.
[7] 刘向东 .冰雪覆盖条件下户外绝缘子绝缘性能研究[D].沈阳工业大学,2002.
[8] Farzaneh M;Zhang J;Aboutorabi S S.Effects of Insulator Profile on the Critical Condition of AC Arc Propagation on Ice-covered Insulators[A].Cancun,2002:383-387.
[9] Farzaneh M;Farzaneh-Dehkordi J;Zhang,J.Flashover Performance of EHV Station Post Insulators Covered with Ice[A].Colorado,2004:37-40.
[10] 苑吉河,蒋兴良,张志劲,胡建林,孙才新.低气压下三种覆冰支柱绝缘子直流闪络特性研究[J].中国电机工程学报,2005(15):12-15.
[11] M. Farzaneh;T. Baker;A. Bernstorf;J. T. Burnham;T. Carreira;E. Cherney;W. A. Chisholm;R. Christman;R. Cole;J. Cortinas;C. de Tourrell;J. E Drapeau;J. Farzaneh-Dehkordi;S. Fikke;R. Gorur;T. Grisham;I. Gutman;J. Kuffel;A. Phillips .Selection of Station Insulators With Respect to Ice and Snow - Part I: Technical Context and Environmental Exposure[J].IEEE Transactions on Power Delivery,2005(1):264-270.
[12] Farzaneh M;Volat C;Gakwaya A.Electric Field Modelling Around an Ice-covered Insulator Using Boundary Element Method[A].Anaheim,2000:349-355.
[13] Christophe Volat;Masoud Farzaneh .Three-Dimensional Modeling of Potential and Electric-Field Distributions Along an EHV Ceramic Post Insulator Covered With Ice - Part I: Simulations of a Melting Period[J].IEEE Transactions on Power Delivery,2005(3):2006-2013.
[14] C. Volat;M. Farzaneh .Three-Dimensional Modeling of Potential and Electric-Field Distributions Along an EHV Ceramic Post Insulator Covered With Ice - Part II: Effect of Air Gaps and Partial Arcs[J].IEEE Transactions on Power Delivery,2005(3):2014-2021.
[15] 苑吉河,蒋兴良,张志劲,舒立春,孙才新.光滑支柱绝缘子覆冰直流放电特性试验研究[J].高电压技术,2006(01):8-10.
[16] Volat C;Meghnefi F;Farzaneh M.Analysis of Leakage Current of an Ice-Covered Insulator During Ice Accretion[A].Dallas,2006:121-126.
[17] F. Meghnefi;C. Volat;M. Farzaneh .Temporal and Frequency Analysis of the Leakage Current of a Station Post Insulator during Ice Accretion[J].IEEE transactions on dielectrics and electrical insulation: A publication of the IEEE Dielectrics and Electrical Insulation Society,2007(6):1381-1389.
[18] Zhang J;Farzaneh M.Modeling of Flashover on IceCovered Insulators with Multi Air Gaps[A].Dallas,2006:109-114.
[19] 卢杰 .110kV支柱绝缘子覆冰交流冰闪特性及其防冰措施研究[D].重庆:重庆大学,2008.
[20] 汪涛,胡惠然,付军,王玮,黄可望,李晓辉.在结冰状态下一次设备闪络事故分析[J].高电压技术,2005(12):84-85.
[21] 李爱民.覆冰绝缘子串的交流放电特性及绝缘子串防冰闪措施[J].青海电力,1995(03):21-23.
[22] 盛道伟 .110kV覆冰绝缘子串操作冲击放电特性研究[D].重庆大学,2008.
[23] Udo T;Tada T;Watanabe Y et al.Switching Surge Sparkover Characteristics of Air Gaps and Insulator Strings Under Practical Conditions[J].IEEE Transactions on Power Apparatus and Systems,1968,PAS-87(02):361-367.
[24] Jaiswal V;Farzaneh M;Lowther D A.Calculation of Potential Distributions Along Semiconducting Glazed Insulator for Impulse Voltages Under Icing Conditions[A].Montveal,2003:631-634.
[25] Zhang J;Guerrero T;Farzaneh M.Experimental Study of Flashover Performance of Ice-covered Insulators Under Impulse Voltages[A].,2004:635-638.
[26] Guerrero T;Farzaneh M;Zhang J.Impulse Voltage Performance of Ice-covered Post Insulators[A].Tennessee,2005:325-328.
[27] V. Jaiswal;M. Farzaneh;D.A. Lowther .Impulse flashover performance of semiconducting glazed station insulator under icing conditions based on field calculations by finite-element method[J].IEE proceedings. Generation, transmission, and distribution,2005(6):864-870.
[28] Jaiswal V;Farzaneh M.Flashover Performance of a Semi-conducting Glazed Post Station Insulator Under Icing Conditions based on Electric Field Distributions[A].,2005:10-13.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%