欢迎登录材料期刊网

材料期刊网

高级检索

为满足牙种植体对高强度、低模量钛合金的需要,设计开发了一种具有较低弹性模量和较高强度的新型医用TB12亚稳β钛合金.研究了固溶处理和时效处理对制备的φ8mm TB12钛合金热轧棒材力学性能的影响.研究结果表明:TB12钛合金经过780~850℃×0.5h的热处理即可实现完全固溶处理.在固溶状态TB12钛合金具有近60GPa的较低弹性模量、1000Mpa的较高抗拉强度、优良的抗剪强度和良好的塑性,满足生物医用钛合金所需要的高强度和低模量的匹配.在固溶时效状态,TB12钛合金具有高达1300Mpa的高强度和大于5%的延伸率.

参考文献

[1] Paszenda Z.Application problems of implants used in interventional cardiology[J].Information Technologies in Biomedicine,2008(47):15-27.
[2] Ti based biomaterials, the ultimate choice for orthopaedic implants - A review[J].Progress in materials science,2009(3):397.
[3] Long M;Rack HJ .Titanium alloys in total joint replacement--a materials science perspective.[J].Biomaterials,1998(18):1621-1639.
[4] Niinomi M. .Mechanical properties of biomedical titanium alloys[J].Materials Science & Engineering, A. Structural Materials: Properties, Misrostructure and Processing,1998(1/2):231-236.
[5] Daisuke K;Niinomi M;Morinaga M et al.Design and mechanical properties of new β type titanium alloys for implant materials[J].Materials Science and Engineering A,1998,243:244-249.
[6] Rack HJ;Qazi JI .Titanium alloys for biomedical applications[J].Materials science & engineering, C. Biomimetic and supramolecular systems,2006(8):1269-1277.
[7] Hanada S;Matsumoto H;Watanabe W .Mechanical compatibility of titanium implants in hard tissues[J].International Congress Series,2005,1284:239-247.
[8] 王卫民,林劭华,曹继敏,张占英,樊亚军,罗斌莉,李雷.热加工工艺对医用TC4合金棒材显微组织的影响[J].钛工业进展,2012(03):14-18.
[9] 张亚峰,于振涛,牛金龙,皇甫强,余森,麻西群.加工及热处理对Ti5ZrMo15Nb钛合金组织和性能的影响[J].钛工业进展,2010(04):30-33.
[10] Niinomi M. .Mechanical properties of biomedical titanium alloys[J].Materials Science & Engineering, A. Structural Materials: Properties, Misrostructure and Processing,1998(1/2):231-236.
[11] Okazaki Y.;Tateishi T.;Ito Y.;Rao S. .Cytocompatibility of various metal and development of new titanium alloys for medical implants[J].Materials Science & Engineering, A. Structural Materials: Properties, Misrostructure and Processing,1998(1/2):250-256.
[12] Yu Sen;Yu Zhentao;Wang Gui et al.Biocompatibility and osteoinduction of active porous calcium-phosphate films on novel Ti-3Zr-2Sn-3Mo-25Nb biomedical alloy[J].Colloids and Surfaces B:Biointerfaces,2011,85:103-115.