欢迎登录材料期刊网

材料期刊网

高级检索

为建立基于泄漏电流特征量的复合绝缘子憎水性能诊断方法,研究了在饱和湿度情况下,污秽度和憎水性能对泄漏电流最大值、泄漏电流出现次数及累积放电量的影响,用聚类分析法对复合绝缘子的憎水性能进行诊断。结果表明:泄漏电流最大值随污秽度和憎水性等级的变大呈增加趋势,污秽度和憎水性能影响泄漏电流幅值的区间不同,污秽度主要影响泄漏电流的低幅值部分,而憎水性能主要影响泄漏电流的高幅值部分,造成这种差异的原因是污秽度和憎水性能对复合绝缘子表面电阻的影响不同;污秽度对复合绝缘子表面累积放电量的影响更明显。使用聚类分析法,选取的泄漏电流特征量能够实现对复合绝缘子憎水性能的诊断。

To establish a diagnosis method of hydrophobicity of composite insulator based on leakage cur-rent characteristic, the effects of pollution degree and hydrophobicity on the maximum value of leakage current, occurrence number of leakage current and accumulated discharge capacity were studied under the condition of saturated humidity, and the hydrophobicity of the composite insulator was diagnosed by clus-ter analysis method. The results show that the maximum value of leakage current increases with the in-crease of pollution degree and hydrophobicity. The pollution degree and hydrophobicity affect the the different amplitude range of leakage current. The pollution degree primarily affects the low amplitude part of leakage current, while the hydrophobicity affects the high amplitude part of leakage current, which is because the effcts of pollution degree and hydrophobicity on the surface resistance of the composite insulator are different. The effect of pollution degree on the accumulated discharge capacity of the composite insulator is more obvious. The selected leakage current characteristic can realize the diagnosis of hydrophobicity of the composite insulator by the cluster analysis method.

参考文献

[1] 张仁豫.绝缘污秽放电[M].北京:水利电力出版社,1994
[2] 顾乐观;孙才新.电力系统的污秽绝缘[M].重庆:重庆大学出版社,1990
[3] 蒋兴良,李名加,司马文霞,孙才新,王进华.污湿环境中合成绝缘子憎水性影响因素分析[J].高电压技术,2002(09):5-6,33.
[4] 吴光亚,蔡炜,肖国英,顾光和,张锐,徐涛.复合绝缘子的运行特性及可靠性分析[J].电瓷避雷器,2004(01):3-9.
[5] 刘泽洪.复合绝缘子使用现状及其在特高压输电线路中的应用前景[J].电网技术,2006(12):1-7.
[6] 蒋兴良;舒立春;孙才新.电力系统的污秽绝缘与覆冰绝缘[M].北京:中国电力出版社,2009
[7] 张福林 .合成绝缘子运行发生不明闪络的原因浅析[J].中国电力,2002,33(06):59-61.
[8] 关志成,王绍武,梁曦东,王黎明,范炬.我国电力系统绝缘子污闪事故及其对策[J].高电压技术,2000(06):37-39.
[9] Riquel G;Spangenberg E .Review of in Service Diagnostic Testing of Composite Insulators[J].Electra,1996,169(12):105-119.
[10] D. L. Williams;A. Haddad;A. R. Rowlands;H. M. Young;R. T. Waters .Formation and characterization of dry bands in clean fog on polluted insulators[J].IEEE transactions on dielectrics and electrical insulation: A publication of the IEEE Dielectrics and Electrical Insulation Society,1999(5):724-731.
[11] Ramirez I;Fierro J L.Criteria for the Diagnostic of Pollut-ed Ceramic Insulators based on the Leakage Current Moni-toring Technique[A].Austin Texas,1999:715-719.
[12] 刘晓安.复合绝缘子性能检测方法简析[J].西北电力技术,2004(01):51-53.
[13] 王海跃,李香龙,汲胜昌,李彦明.合成绝缘子在线检测方法的现状与发展[J].高电压技术,2005(04):37-42.
[14] Tomotaka Suda .Frequency Characteristics of Leakage Current Waveforms of a String of Suspension Insulators[J].IEEE Transactions on Power Delivery,2005(1):481-487.
[15] Sebo S A;Sakich J D;Zhao T B.Evalution of Leakage Current Pulse Data of Polymer Insulator Aging Tests[A].Sweden,1998:425-429.
[16] 程养春,李成榕,沈小军,陈勉,陈润华.几种合成绝缘子带电检测方法的比较[J].高电压技术,2004(06):35-37.
[17] Felix Amarh;George G. Karady;Raji Sundararajan .Linear stochastic analysis of polluted insulator leakage current[J].IEEE Transactions on Power Delivery,2002(4):1063-1069.
[18] 李璟延 .污秽绝缘子泄漏电流特性与污秽预警方法研究[D].重庆大学,2010.
[19] 关志成,毛颖科,王黎明.污秽绝缘子泄漏电流特性研究[J].高电压技术,2008(01):1-6.
[20] 王伟 .高压线路不良绝缘子脉冲电流式检测方法的研究[D].北京:华北电力大学,1994.
[21] 姚继莎 .自然环境中复合绝缘子憎水性变化特性及机理的研究[D].华北电力大学(北京),2006.
[22] Hiroya Hornma;Lee C R;Kuroyagi T;et a1.Evaluation of Time Variation of Hydrophobicity of Silicone Rubber using Dynamic Contact Angle Measurement[A].,2000:637-640.
[23] 陈海东 .合成绝缘子电场的陡变与不明闪络原因的研究[D].西安理工大学,2007.
[24] 熊俊,李成榕,赵林杰,张书琦,毕永江.恒压洁净雾环境中复合绝缘子表面泄漏电流特征参量分析[J].电网技术,2007(15):70-74.
[25] IEC 61245-1993.Artificial Pollution Tests on High-voltage Insulators to be Used on DC System[S].
[26] 汪增福.模式识别[M].合肥:中国科学技术大学出版社,2010
[27] 贺博,林辉.高压绝缘子污闪过程特征量的分类和判别[J].高压电器,2006(03):172-175,178.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%