本文讨论了一种可适用于气体液化的新型脉冲管制冷系统:在该系统中,回热器被间壁式换热器所取代。切换阀置于脉冲管冷端,和脉冲管作为一个整体,起气体膨胀机的作用。我们建立了相应的实验装置以测量整个系统的性能。利用空气作介质,系统进出口温降为63.6 K,绝热膨胀效率可达42%。利用氦气作工质,脉冲管冷端最低温度达160 K,每1 K有0.75 W的制冷量。

This paper discusses a new pulse tube refrigerationsystem that can be applied to gas-liquefaction, inwhich the regenerator is replaced with recuperative heat exchanger. The switching valve together with pulse tube woks as a gas expander. Experimental apparatuses are set up to investigate the performance of the whole system. Using pure air as working substance, the temperature drop between the inlet and the out gases is 63.6 K and the adiabatic expansion efficiency higher than 40% is achieved. Using He as working substance, the pulse tube refrigerator reaches 160 K at the cold end and achieves 0.75 W/K.

参考文献

[1] Gifford W E;Longsworth R C .Pulse Tube Refrigeration[J].Journal of Engineering for Industry-Transactions of the ASME,1964,86:264.
[2] Mikulin E I;Tarasov A A;Shkreb A et al.Low TemperatureExpansion Pulse Tubes[J].Advances in Cryogenic Engineering,1984,29:629.
[3] 梁惊涛.大功率低温切换阀式脉冲管制冷机[A].,1996
[4] 张祉佑;石秉三.低温技术原理与装置[M].北京:机械工业出版社,1987
[5] 沈裕浩;高原.多层孔板换热器研究[J].低温工程,1984(03):95.
[6] 沈裕浩.多层孔板换热器研究[J].低温工程,1981(04):95.