镁合金因其良好的生物相客性、生物降解-吸收性以及与自然骨相匹配的生物力学性能,有望成为理想的新型生物医用金属材料.然而,镁在生理环境下过快的降解速率成为制约其生物医用的主要瓶颈,因此,镁合金的生物降解控制至关重要.综述了镁合金生物降解机理及其主要控制技术,如开发高纯合金或新合金、热处理及成形加工、表面处理的国内外最新研究进展,并展望了其未来的研究方向.
参考文献
[1] | Harpreet S. Brar;Manu O. Platt;Malisa Sarntinoranont .Magnesium as a Biodegradable and Bioabsorbable Material for Medical Implants[J].JOM,2009(9):31-34. |
[2] | Rongchang Zeng;Wolfgang Dietzel;FrankWitte;Norbert Hort;Carsten Blawert .Progress and Challenge for Magnesium Alloys as Biomaterials[J].Advanced Engineering Materials,2008(8):B3-B14. |
[3] | Witte F;Kaese V;Haferkamp H;Switzer E;Meyer Lindenberg A;Wirth CJ;Windhagen H .In vivo corrosion of four magnesium alloys and the associated bone response.[J].Biomaterials,2005(17):3557-3563. |
[4] | Zhang E L;Xu L P;Yu G N .In vivo evaluation of biodegradable magnesium alloy bone implant in the first 6 months implantation[J].Journal of Biomedical Materials Research Part A,2009,90(03):882. |
[5] | Staiger MP;Pietak AM;Huadmai J;Dias G .Magnesium and its alloys as orthopedic biomaterials: A review[J].Biomaterials,2006(9):1728-1734. |
[6] | Mani G;Feldman MD;Patel D;Agrawal CM .Coronary stents: A materials perspective[J].Biomaterials,2007(9):1689-1710. |
[7] | Xin Y;Huo K;Tao H .Influence of aggressive ions on the degradation behavior of biomedical magnesium alloy in physiological environment.[J].Acta biomaterialia,2008(6):2008-2015. |
[8] | Akiko Yamamoto;Sachiko Hiromoto .Effect of inorganic salts, amino acids and proteins on the degradation of puremagnesium in vitro[J].Materials science & engineering, C. Biomimetic and supramolecular systems,2009(5):1559-1568. |
[9] | Levesque J;Hermawan H;Dube D;Mantovani D .Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials.[J].Acta biomaterialia,2008(2):284-295. |
[10] | Witte F;Hort N;Vogt C et al.Degradable biomaterials based on magnesium corrosion[J].Current Opinion in Solid State and Materials Science,2008,12(5-6):63. |
[11] | Witte F;Fischer J;Nellesen J;Crostack HA;Kaese V;Pisch A;Beckmann F;Windhagen H .In vitro and in vivo corrosion measurements of magnesium alloys[J].Biomaterials,2006(7):1013-1018. |
[12] | Zhang Y J;Yan C W;Wang F H et al.Electrochemical behaviors of anodized magnesium alloy AZ91D in chloride containing aqueous solution[J].Corrosion Science,2005,47(11):2816. |
[13] | 任伊宾,黄晶晶,杨柯,张炳春,姚治铭,王浩.纯镁的生物腐蚀研究[J].金属学报,2005(11):1228-1232. |
[14] | Guangling Song .Control of biodegradation of biocompatable magnesium alloys[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,2007(4):1696-1701. |
[15] | Li Z;Gu X;Lou S;Zheng Y .The development of binary Mg-Ca alloys for use as biodegradable materials within bone.[J].Biomaterials,2008(10):1329-1344. |
[16] | Yizao Wan;Guangyao Xiong;Honglin Luo;Fang He;Yuan Huang;Xiaoshong Zhou .Preparation and characterization of a new biomedical magnesium-calcium alloy[J].Materials & design,2008(10):2034-2037. |
[17] | Xu LP;Zhang EL;Yin DS;Zeng SY;Yang K .In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application[J].Journal of Materials Science. Materials in Medicine,2008(3):1017-1025. |
[18] | HE YaoHua,TAO HaiRong,ZHANG Yan,JIANG Yao,ZHANG ShaoXiang,ZHAO ChangLi,LI JiaNan,ZHANG BeiLei,SONG Yang,ZHANG XiaoNong.Biocompatibility of bio-Mg-Zn alloy within bone with heart, liver, kidney and spleen[J].科学通报(英文版),2009(03):484-491. |
[19] | Bruno Zberg;Peter J. Uggowitzer;Jorg F. Loffler .MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants[J].Nature materials,2009(11):887-891. |
[20] | Hanzi,AC;Gunde,P;Schinhammer,M;Uggowitzer,PJ .On the biodegradation performance of an Mg-Y-RE alloy with various surface conditions in simulated body fluid.[J].Acta Biomaterialia,2009(1):162-171. |
[21] | Liu C L;Xin Y C;Tang G Y et al.Influence of heat treatment on degradation behavior of biodegradable diecast AZ63 magnesium alloy in simulated body fluid[J].Materials Science and Engineering A:Structural Materials Properties Microstructure and Processing,2007,456(1-2):350. |
[22] | Majumdar JD;Bhattacharyya U;Biswas A;Manna I .Studies on thermal oxidation of Mg-alloy (AZ91) for improving corrosion and wear resistance[J].Surface & Coatings Technology,2008(15):3638-3642. |
[23] | H. Wang;Y. Estrin;Z. Zuberova .Bio-corrosion of a magnesium alloy with different processing histories[J].Materials Letters,2008(16):2476-2479. |
[24] | Al-Abdullat Y;Tsutsumi S;Nakajima N et al.Surface modification of magnesium by NaHCO3 and corrosion behavior in Hankˊs solution for new biomaterial applications[J].Materials Transactions,2001,42(08):1777. |
[25] | Gu XN;Zheng W;Cheng Y .A study on alkaline heat treated Mg-Ca alloy for the control of the biocorrosion rate.[J].Acta biomaterialia,2009(7):2790-2799. |
[26] | Xu L;Pan F;Yu G;Yang L;Zhang E;Yang K .In vitro and in vivo evaluation of the surface bioactivity of a calcium phosphate coated magnesium alloy.[J].Biomaterials,2009(8):1512-1523. |
[27] | Zhang Y J;Mei W .Controlling the biodegradation rate of magnesium using sol-gel and apatite coatings[J].International Journal of Modern Physics B,2009,23(6-7):1897. |
[28] | Li LC;Gao JC;Wang Y .Evaluation of cyto-toxicity and corrosion behavior of alkali-heat-treated magnesium in simulated body fluid[J].Surface & Coatings Technology,2004(1):92-98. |
[29] | Characterization and degradation behavior of AZ31 alloy surface modified by bone-like hydroxyapatite for implant applications[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,2009(13/14):6433. |
[30] | Song Y W;Shan D Y;Han E H .Electrodeposition of hydroxyapatite coating on AZ91D magnesium alloy for biomaterial applieation[J].Materials Letters,2008,62(17-18):3276. |
[31] | 郭磊,刘魁,张世亮,高晓宇,黄晶晶,杨柯.CA-P/AZ31B镁合金的生物相溶性研究[J].稀有金属材料与工程,2009(01):99-103. |
[32] | Zhang Y J;Yan C W;Wong F H et al.Study on the environmentally friendly anodizing of AZ91D magnesium alloy[J].Surface and Coatings Technology,2002,161(01):36. |
[33] | Shi P;Ng W F;Wang M H et al.Improvement of corrosion resistance of pure magnesium in Hanks'solution by microarc oxidation with sol-gel TiO2 sealing[J].Journal of Alloys and Compounds,2009,469(1-2):286. |
[34] | 张永君 .电压阶跃微弧氧化方法[P].中国,ZL 2007 1 0032665.0,2008-10-01. |
[35] | 王飞,王钢,孟祥翔,张永君,张大保.新型镁合金皮内刺激与致敏实验研究[J].中国矫形外科杂志,2009(13):1013-1016. |
[36] | 孟祥翔,王钢,王飞,张永君,张大保.新型医用镁合金材料的体外生物相容性研究[J].中华创伤骨科杂志,2009(03):243-246. |
[37] | Zhang XP;Zhao ZP;Wu FM;Wang YL;Wu J .Corrosion and wear resistance of AZ91D magnesium alloy with and without microarc oxidation coating in Hank's solution[J].Journal of Materials Science,2007(20):8523-8528. |
[38] | 黄晶晶,任伊宾,张炳春,杨柯.可降解镁植入材料表面涂层的制备及其性能[J].中国有色金属学报,2007(09):1465-1469. |
[39] | 许鑫华,程静,张春怀,闫学良,朱天兵,姚康德,曹路,刘寅.医用镁合金的生物腐蚀及高分子涂层处理[J].稀有金属材料与工程,2008(07):1225-1228. |
[40] | 赵常利,张绍翔,何慈晖,李佳楠,张蓓蕾,张小农.生物医用镁合金表面PLGA涂层研究[J].功能材料,2008(06):987-989,993. |
[41] | Yang, JX;Jiao, YP;Cui, FZ;Lee, IS;Yin, QS;Zhang, Y .Modification of degradation behavior of magnesium alloy by IBAD coating of calcium phosphate[J].Surface & Coatings Technology,2008(22/23):5733-5736. |
[42] | Liu CL;Xin YC;Tian XB;Chu PK .Corrosion behavior of AZ91 magnesium alloy treated by plasma immersion ion implantation and deposition in artificial physiological fluids[J].Thin Solid Films: An International Journal on the Science and Technology of Thin and Thick Films,2007(2/4):422-427. |
[43] | Y.Z. Wan;G.Y. Xiong;H.L. Luo;F. He;Y. Huang;Y.L. Wang .Influence Of Zinc Ion Implantation On Surface Nanomechanical Performance And Corrosion Resistance Of Biomedical Magnesium-calcium Alloys[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,2008(17):5514-5516. |
[44] | 杨黎晖,李峻青,姜巍巍,张密林.镁合金表面处理技术的研究进展[J].中国腐蚀与防护学报,2008(05):316-320. |
[45] | Witte F;Feyerabend F;Maier P;Fischer J;Stormer M;Blawert C;Dietzel W;Hort N .Biodegradable magnesium-hydroxyapatite metal matrix composites.[J].Biomaterials,2007(13):2163-2174. |
[46] | Zhang E L;Xu L P;Yang K .Formation by ion plating of Ticoating on pure Mg for biomedical applications[J].Scripta Materialia,2005,53(05):523. |
[47] | 高亚丽,熊党生,王存山,潘学民.医用镁合金激光熔覆羟基磷灰石涂层初探[J].特种铸造及有色合金,2009(04):305-307. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%