欢迎登录材料期刊网

材料期刊网

高级检索

生物传感器是一种在多学科交叉背景下发展起来的新型测试装置,其中光学生物传感器因具有快速、灵敏、准确和高选择性等特点而最为引人瞩目.综述了光学生物传感器的原理、结构和分类;对比讨论了各类光学生物传感器的特性、应用领域、存在的主要问题及其今后的发展趋势;评述了以新型无机材料作为标记物的光致荧光生物传感器的研究意义以及发展前景.

参考文献

[1] O'Neill P M;Fletcher J E;Stafford C G;et a1 .[J].Sensors and Actuators B-Chemical,1995,29:79.
[2] Dodeigne C. .Review Chemiluminescence as a diagnostic tool. A review[J].Talanta: The International Journal of Pure and Applied Analytical Chemistry,2000(3):415-439.
[3] D'Orazio P .Biosensors in clinical chemistry.[J].Clinica chimica acta: International journal of clinical chemistry and applied molecular biology,2003(1/2):41-69.
[4] Ulber R;Frerichs J G;Beutel S .[J].Analytical Biochemistry,2003,376:342.
[5] 许丹科;马立人;汪尔康.21世纪的分析化学.生物传感器在军事医学中的发展[M].北京:科学出版社,1999:255.
[6] Cooper M A .[J].Nature Reviews Drug Discovery,2002,1:515.
[7] Kroger S;Piletsky S;Turner A P F .[J].Marine Pollution Bulletin,2002,45:24.
[8] 邓家祺;高鸿.分析化学前沿.生物传感器[M].北京:科学出版社,1991:131.
[9] Pearson JE;Gill A;Vadgama P .Analytical aspects of biosensors.[J].Annals of Clinical Biochemistry: Journal of the Association of Clinical Biochemists in Association with de Nederlandse Vereniging voor Klinische Chemie,2000(Pt.2):119-145.
[10] Luppa P B;Sokoll L J et al.[J].Chimica Acta,2001,314:1.
[11] 章竹君.光导纤维化学传感器:高鸿.分析化学前沿[M].北京:科学出版社,1991:49.
[12] 李瑛绣;朱连德;朱果逸 .[J].分析测试学报,2002,21:89.
[13] 钱军民,李旭祥.固定化技术在生物传感器中的应用[J].传感器技术,2001(07):6-10.
[14] Gill Ⅰ .[J].CHEMISTRY OF MATERIALS,2001,13:3404.
[15] Jin W;Brennan J D .[J].Analytica Acta,2002,461:1.
[16] 章竹君;秦伟 .[J].分析科学学报,1997,13:72.
[17] Coulet P R;Blum L J .[J].Trends in Analytical Chemistry,1992,11:57.
[18] Blum L J;Gautier S M;Berger A et al.[J].Sensors and Actuators B-Chemical,1995,29:1.
[19] Michel P E;Gautier S M;Blum L J .[J].Enzyme and Microbial Technology,1997,21:108.
[20] Hava T .[J].Bulletin of the Chemical Society of Japan,1989,62:2844.
[21] 张新荣;封满良 .[J].化学学报,1994,52:83.
[22] Sagi E.;Hever N.;Rosen R.;Bartolome AJ.;Premkumar JR.;Ulber R.;Lev O.;Scheper T.;Belkin S. .Fluorescence and bioluminescence reporter functions in genetically modified bacterial sensor strains[J].Sensors and Actuators, B. Chemical,2003(1/3 special issue si):2-8.
[23] Dollard MA;Billard P .Whole-cell bacterial sensors for the monitoring of phosphate bioavailability[J].Journal of Microbiological Methods,2003(1):221-229.
[24] Roda A;Guardigli M;Michelini E et al.[J].Analytical Chemistry,2003,75:462.
[25] Li W;Chen J;Xiang B R et al.[J].化学学报,2001,59:109.
[26] 李军,王柯敏,肖丹,羊小海,何晓晓.基于荧光增强效应的可逆型牛血清白蛋白光化学生物传感器研究[J].分析化学,2002(03):257-261.
[27] Robinson G A;Attridge J W;Deaeon J K et al.[J].Sensors and Actuators B-Chemical,1993,11:235.
[28] Daniels P B;Fletcher J E;O'Neill P M et al.[J].Sensors and Actuators B-Chemical,1995,11:235.
[29] Domenici C;Schirone A;Celebre M et al.[J].Biosensors and Bioelectronics,1995,10:371.
[30] Yan J L;Wang G L;Majima K et al.[J].Analytical Chemistry,2001,73:1869.
[31] Selvin PR .Principles and biophysical applications of lanthanide-based probes.[J].Annual Review of Biophysics and Biomolecular Structure,2002(0):275-302.
[32] Arden-Jacob J;Frantzeskos J;Kemnitzer N U et al.[J].Spectrochimica Acta,2001,57:2271.
[33] Bnjchez J M;Moronne M;Gin P et al.[J].Science,1998,281:2013.
[34] Chan W C W;Nie S M .[J].Science,1998,281:2016.
[35] Dahan M.;Pinaud F.;Chemla DS.;Alivisatos AP.;Sauer M. Weiss S.;Laurence T. .Time-gated biological imaging by use of colloidal quantum dots[J].Optics Letters,2001(11):825-827.
[36] Alivisatos P .[J].Pure and Applied Chemistry,2000,72:3.
[37] Han M Y;Gao X H;Su J Z et al.[J].Nature Biotechnology,2001,19:631.
[38] Santra S;Zhang P;Wang K M et al.[J].Analytical Chemistry,2001,73:4988.
[39] An B L;Gong M L;Ye J Q et al.[J].Journal of Rare Earths,2003,21:514.
[40] Lin Z B;Su X G;Zhang H et al.[J].Chemical Journal of Chinese Universities-Chinese,2003,24:216.
[41] Liedberg B;Nylander C;Lundstrom Ⅰ .[J].Biosensors and Bioelectronics,1995,10:1.
[42] Rothmund M;Schuetz A;Brecht A et al.[J].Fresenius'Journal of Analytical Chemistry,1997,359:15.
[43] Cush R;Cronin J M;Stewart W J et al.[J].Biosensors and Bioelectronics,1993,8:347.
[44] Lukosz W;Stamm C .[J].Sensors and Actuators A-physical,1991,25-27:185.
[45] Lin B.;Qiu J.;Gerstenmeier J.;Li P.;Pien HM.;Pepper J.;Cunningham B. .A label-free optical technique for detecting small molecule interactions[J].Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices,2002(9):827-834.
[46] Leatherbarrow R J;Edwards P R .[J].Current Opinion in Chemical Biology,1999,3:544.
[47] Rich R L;Myszka D G .[J].Trends in Microbiology,2003,11:124.
[48] Morgan C L;Newman D L;Price C P .[J].Clinical Chemistry,1996,42:193.
[49] Kubitschko S;Spinkle J;Bruckner T et al.[J].Analytical Biochemistry,1997,253:112.
[50] Nikitin PI.;Valeiko MV.;Gorshkov BG. .New direct optical biosensors for multi-analyte detection[J].Sensors and Actuators, B. Chemical,2003(1/3 special issue si):46-51.
[51] 陈扬,陆祖宏.发光标记分析及其在核酸检测中的应用[J].化学通报,2001(09):537-546.
[52] Xing W L;Chao F H;Jiang Z H et al.[J].Chem J Chinese,2000,21:873.
[53] Dufford R T;Nightingale D;Gaddum L W .[J].Journal of the American Chemical Society,1927,49:1858.
[54] Harvey N .[J].Journal of Physical Chemistry,1929,33:1456.
[55] Knight A W;Greenway G M .[J].Analyst,1994,119:879.
[56] Yu H;Bruno J G;Chang T et al.[J].Journal of Bioluminescence and Chemiluminescence,1995,10:239.
[57] Deaver D R .[J].NATURE,1995,337:758.
[58] Kenten J H;Casadei J;Link J et al.[J].Clinical Chemistry,1991,37:1626.
[59] Fahnrich K A;Pravda M;Guilbault G G .[J].Talanta,2001,54:531.
[60] Yang M L;Liu C Z;Qian K J et al.[J].Analyst,2002,127:1267.
[61] Marquette CA.;Degiuli A.;Blum LJ. .Electrochemiluminescent biosensors array for the concomitant detection of choline, glucose, glutamate, lactate, lysine and urate[J].Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices,2003(5):433-439.
[62] Li J P;Peng T Z;He X R et al.[J].Chemical Journal of Chinese Universities-Chinese,2003,24:404.
[63] Rich RL;Myszka DG .Survey of the year 2001 commercial optical biosensor literature.[J].Journal of molecular recognition: JMR,2002(6):352-376.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%