利用电化学交流阻抗谱(EIS)分析和研究了硫酸盐还原菌(SRB)在银、金、玻碳、Q235碳钢和高钼双相不锈钢电极表面的粘附动力学过程.基于EIS检测数据并通过公式推导提出了评估硫酸盐还原菌(SRB)附着过程的双电层电容变化模型.另外石英晶体微天平(QCM)和扫描电子显微镜(SEM)也被用来表征细菌粘附的动力学过程.

参考文献

[1] 刘光洲,吴建华.海洋微生物腐蚀的研究进展[J].腐蚀与防护,2001(10):430-433.
[2] 李松梅,刘建华,武海燕,杨应广.一种控制腐蚀微生物的新方法--电化学杀菌[J].腐蚀与防护,2004(06):256-259,262.
[3] 刘玉秀,刘贵昌,战广深.硫酸盐还原菌引起的微生物腐蚀的研究进展[J].腐蚀与防护,2002(06):245-248,253.
[4] 朱绒霞.有硫酸盐还原菌存在时J55套管钢的极化行为[J].腐蚀与防护,2001(04):147-148,172.
[5] George O'Toole;Heidi B. Kaplan;Roberto Kolter .Biofilm formation as microbial development[J].Annual Review of Microbiology,2000(0):49-79.
[6] Tan, L;Xie, QJ;Jia, XE;Guo, ML;Zhang, YY;Tang, H;Yao, SZ .Dynamic measurement of the surface stress induced by the attachment and growth of cells on Au electrode with a quartz crystal microbalance[J].Biosensors & Bioelectronics,2009(6):1603-1609.
[7] A.Toby A.Jenkins;Richard ffrench-constant;Angus Buckling;David J.Clarke;Katherine Jarvis .Study of the Attachment of Pseudomonas aeruginosa on Gold and Modified Gold Surfaces Using Surface Plasmon Resonance[J].Biotechnology Progress,2004(4):1233-1236.
[8] Munoz-Berbel X;Munoz FJ;Vigues N;Mas J .On-chip impedance measurements to monitor biofilm formation in the drinking water distribution network[J].Sensors and Actuators, B. Chemical,2006(1/2):129-134.
[9] Hisao Morisaki;Misa Sugimoto;Haruki Shiraishi .Attachment of bacterial cells to carbon electrodes[J].Bioelectrochemistry,2000(1):21-25.
[10] Ping Geng;Xinai Zhang;Weiwei Meng;Qingjiang Wang;Wen Zhang;Litong Jin;Zhen Feng;Zirong Wu .Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy[J].Electrochimica Acta,2008(14):4663-4668.
[11] Ruan CM.;Yang LJ.;Li YB. .Immunobiosensor chips for detection of Escherichia coli O157 : H7 using electrochemical impedance spectroscopy[J].Analytical chemistry,2002(18):4814-4820.
[12] Munoz-Berbel X;Vigues N;Jenkins ATA;Mas J;Munoz FJ .Impedimetric approach for quantifying low bacteria concentrations based on the changes produced in the electrode-solution interface during the pre-attachment stage[J].Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices,2008(10):1540-1546.
[13] Munoz-Berbel X;Vigues N;Mas J;Toby A;Jenkins A;Munoz FJ .Impedimetric characterization of the changes produced in the electrode-solution interface by bacterial attachment[J].Electrochemistry communications,2007(11):2654-2660.
上一张 下一张