欢迎登录材料期刊网

材料期刊网

高级检索

A 2D full cell thermo-electric model of 160kA drained cell was set up using finite element code to calculate its freeze profile,then the drained cell model was modified according to the freeze profile computed and its heat balance was calculated.Compared with that of a 160kA conventional Hall-Heroult cell(H-H cell),though the melts volume of the drained cell reduced greatly,the whole heat loss from it didn't drop down apparently,and an analysis was presented in the paper.On the other hand,the anodecathode distance(ACD)of a drained cell was much less than that of a H-H cell,so the voltage drop on it and heat produced decreased too,steps should be taken to keep a workable heat balance on a drained cell.

参考文献

[1] Y X Liu.[J].Light Metals,2001(05):26.
[2] H M LuandZ X Qiu .[J].Mining and Metallurgy,2000,9(04):62.
[3] B.G.Yang;P.Z.Yu;X.J.Yu;Z.X.Qiu.[J].Light Metals,2000(05):32.
[4] I G Stedman;G J Houston;R W Shaw;D.D.Juric .[P].US US 5043047,1991.
[5] C Mei;W You;Q P Wang;F.B.Tu .[J].Journal of Central South University of Technology,1997,28(02):38.
[6] W You;Q P Wang;X F Li;C Mei .[J].Transaction of the Nonferrous Metals Society of China,1998,8(04):695.
[7] M DupuisandI Tabsh .[OL].http://www.genisim.qc.ca/website/ansys91.htm
[8] L G Boxall;B W Gamson;J A S Green;S.C.Traougott .[P].US US 4602990,1986.
[9] M Dupuis;Light Metals;B J Welch .[R].TMS,Warrendale,PA,USA,1998.
[10] 刘业翔,李相鹏,赖延清,李劼,周向阳,赵恒勤.Heat balance simulation of drained aluminum reduction cell[J].中国有色金属学会会刊(英文版),2003(05):1199-1202.
[11] A VallandV Lenis.Light Metals[M].TMS,Warrendale,PA,USA,1995:309.
[12] M M AliandA A Mostafa .Light Metals[Z].TMS,Warrendale,PA,USA,1997.