干燥剂除湿复合空调系统与传统的压缩式制冷空调相比,不仅降低了高品位能源消耗,而且可以实现温湿度单独控制,是一项非常有潜力的制冷技术.传统空调系统蒸发器同时承担显热负荷和潜热负荷,而复合空调系统的蒸发器只承担显热负荷.本文主要研究了潜热、显热分级处理对干燥剂除湿复合空调系统热力学特性的影响.
参考文献
[1] | P. L. Dhar;S. K. Singh .Studies on solid desiccant based hybrid air-conditioning systems[J].Applied thermal engineering: Design, processes, equipment, economics,2001(2):119-134. |
[2] | Y. J. Dai;R. Z. Wang;H. F. Zhang;J. D. Yu .Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning[J].Applied thermal engineering: Design, processes, equipment, economics,2001(12):1185-1202. |
[3] | P R Burns;J W Mitchell .Hybrid Desiccant Cooling Systems in Supermarket application[J].ASHRAE Transactions,1985,91:457-468. |
[4] | X. J. Zhang;Y. J. Dai;R. Z. Wang .A simulation study of heat and mass transfer in a honeycombed rotary desiccant dehumidifier[J].Applied thermal engineering: Design, processes, equipment, economics,2003(8):989-1003. |