欢迎登录材料期刊网

材料期刊网

高级检索

The electromagnetic dam (EMD) in twin-roll strip caster was simulated with FEM. The results show that the direction and magnitude of Lorentz force distributing in the EMD changed in a period. The negative part is about 30% of the positive part, and the acting time of the negative force is about 40% of a period. In order to prevent the liquid steel from leaking efficiently, the distance between two poles should be the same from the top to the bottom of the EMD, otherwise the magnetic induction will be very small at the top and large at the bottom.

参考文献

[1] Moon;Hee-Kyung;Park.Development of Strip Casting Process at POSCO/RIST[A].Cambridge,MA,United States:Minerals,Metals and Materials Society,2000:507-511.
[2] Steffen;Rolf;Tacke et al.State of Strip Steel Casting (in German)[J].Stahl und Eisen,1999,119(6-7):129-132.
[3] Takeuchi;Hidemaro;Tanaka.Production of Stainless Steel Strip by Twin-Drum Strip Casting Process[J].Nippon Steel Technical Report,1994(61):46-51.
[4] QIU Yi-qing;DI Hong-shuang;LIU Xiang-hua et al.Technology of Twin-Roll Casting at RAL[J].Iron and Steel,2004,39(zk):550-553.
[5] Cramb;Alan W .New Steel Casting Processes for Thin Slabs and Strip:a Historical Perspective[J].Ironmaking and Steelmaking,1988,15(07):45-60.
[6] 李朝锋,邸洪双,张晓明,王国栋,刘相华.双辊铸轧薄带钢侧封板材料评价及热应力有限元模拟[J].机械工程学报,2002(11):96-99.
[7] MA Yong-lin;HE You-duo;XU Guang-yao et al.The Study of the Electromagnetic Stirring in Continuous Casting With Finite Element Method[J].Baotou University of Iron and Steel Technology,1997,16(03):193-197.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%