高级检索

Hydroxyapatite (HAP) coatings were deposited onto titanium substrates by electrophoretic deposition (EPD) fromethanol. The results indicated that the addition of very small amount of HCI resulted in a decrease in the aging timeas well as the suspension concentration required to obtain a coating. In addition, the results revealed the existenceof a critical saturated voltage (Vsat), which had significant effect on the quality of deposition. The mean interfacialshear strengths of HAP coatings after sintering were found to be greater than 13 MPa.

参考文献

[1] P Li K .De Groot and T.Kokubo[J].Journal of Sol-Gel Science and Technology,1998,7:27.
[2] 张建民.电化学法制备生物活性陶瓷材料研究[J].高等学校化学学报,1997(06):961.
[3] F Z Cui;Z S Luo;Q L Feng .[J].Journal of Materials Science:Materials in Medicine,1997,8:403.
[4] I Zhitomistry;L Gal-Or .[J].Journal of Materials Science:Materials in Medicine,1997,8:213.
[5] Z D Feng;Y JIANG;J M ZHANG;R G DU,C J LIN .[J].高等学校化学学报,2000,21(zk):299.
[6] M Jarcho;C H Bolen;M B Thomas;J.Bobick J.F.Kay,R.H.Doremus.[J].Journal of Materials Science,1976(11):2027.
[7] Standard Test Methods for Shear Testing of Porous Metal Coating[Z].ASTM Standard F1044-87
[8] R Damodaran;B.M.Moudgil .Colloids Surfaces A[J].Colloids and Surfaces A:Physicochemical and Engineering Aspects,1993,80:191.
[9] F M Fowkes .[J].Advance in Ceramics,1987,21:411.
[10] M Wei;A J Ruys;M V Swain;S.H.Kim B.K.Milthorpe,C.C.Sorrell .[J].Journal of Materials Science:Materials in Medicine,1999,10:401.