总结了高压输电线引起交流腐蚀的研究现状,阐述了国内外埋地管道在自然敷设和有阴极保护情况下的交流腐蚀判别准则,并对我国高压输电线和油气管道敷设关系的相关要求和标准进行了总结,提出了存在的问题和相应的建议.

Based on the summary of the research on AC corrosion of underground pipelines induced by high voltage transmission lines, the judgment principles of AC corrosion of underground pipelines with or without cathodic protection were introduced. The relevant standards for the relationship between the high voltage transmission line and underground pipeline were summarized. Finally the existing problems and the relevant suggestions for improvement were also put forward.